    Apter Power supports 3607E quotation, termination review, and documentation checks.

3607E

/ 4.9
1001 reviews | Need a Specific Revision?
Triconex 3607E is a sixteen-point non-commoned 48 VDC TMR output module rated to 1 A per point, with individual fuse supervision and hot-spare capability.
In Stock
Ships by Wednesday, September 30
Fast Shipping Available
Get a quick price for 3607E
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3607E

  • Manufacturer:
    Invensys
  • Part Number:
    3607E
  • Product Family:
    Triconex
  • Product Type:
    TMR Digital Output Module
  • Stock:
    1
  • Model:
    3607E
  • Architecture:
    TMR digital output
  • Nominal voltage:
    48 VDC
  • Output points:
    16, non-commoned
  • Voltage range:
    44 to 80 VDC
  • Typical voltage drop:
    Less than 3 V
  • Maximum current per point:
    1 A
  • Surge current:
    5 A for 10 ms
  • Load leakage:
    2 mA maximum
  • Field termination fuse:
    1.25 A fast-acting, one per output
  • Point isolation:
    1,500 VDC
  • Point indication:
    One On or Off indicator per output
  • Module indications:
    PASS, FAULT, ACTIVE
  • Field alarm:
    LOAD/FUSE
  • Color code:
    Light blue
  • Hot spare:
    Supported
  • External termination:
    Separate ETP and cable required
  • Field-power method:
    Power wired to each source output point
  • Tariff Code:
    8537101190
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Control Diagnostics Integration

Features:

  • Sources sixteen separate 48 VDC outputs without combining their field returns.
  • Supports one amp continuously per point and a five-amp pulse lasting up to ten milliseconds.
  • Uses individual 1.25 A fast-acting fuses with a dedicated LOAD/FUSE alarm path.
The current ordering configuration is 3607E, the light-blue 48 VDC member of the Tricon sixteen-point TMR output family.

It is suited to isolated DC actuators and relay circuits that need voted command execution, per-point state indication, and continuous switch supervision.

During commissioning, confirm the 44-80 VDC source, expected leakage sensitivity, transient current, keyed chassis position, and the approved field-termination assembly.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Triconex 3607E: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Operates isolated 48 VDC valve, relay and trip circuits that cannot share a common field return.
  • Fits protective logic that needs command-to-voltage comparison on every individual output path.
  • Allows online module maintenance when the chassis reserves a correctly engineered hot-spare position.
  • Three Main Processor commands are resolved through quadruplicated voting circuitry before each of the sixteen source outputs is driven.
  • Individual point indications show the commanded output state, while PASS, FAULT and ACTIVE lamps report module operating status separately.
  • A correctly configured hot-spare position allows the output function to remain available during an approved online module exchange.
  • Voltage loopback compares the measured field voltage with the voted command without depending on the connected load as the sole switching check.
  • A LOAD/FUSE alarm identifies a disagreement caused by lost field power, an open fuse path or another external voltage fault.
  • Each output is protected by a 1.25 A fast-acting fuse on the approved external termination arrangement.
  • The sixteen non-commoned channels require the documented 44–80 VDC source wiring and individually separated field circuits.
  • Use the compatible 9667-series termination hardware and approved interface cable so point isolation, fusing and field polarity remain intact.
  • Confirm chassis keying, companion hot-spare position and load inrush before transferring control to a replacement module.
Description
Triconex 3607E is a 16-point, non-commoned 48 VDC TMR digital output module for sourcing individually separated field loads in a Tricon safety system. Three processor commands are resolved by quadruplicated voting circuitry before the selected state reaches each external circuit. The arrangement is suited to DC solenoids, relays and other actuators that require point separation and continuous diagnostic coverage.

Independent point-state indication is combined with voltage-loopback supervision of the output switch. LOAD/FUSE annunciation identifies a disagreement between the command and measured field voltage, helping technicians recognize loss of source power, an open fuse path or another external discrepancy without using the connected load as the only proof of switching. Internal channel and voter diagnostics remain distinct from these field-circuit checks.

Each output must remain within the 44–80 VDC range, one-amp continuous limit, permitted surge and documented leakage boundary. A compatible 9667-series termination panel provides individual fusing, and the approved cable preserves the intended field interface. Before an online exchange, verify mechanical keying, field-power continuity, the configured hot-spare position and the load inrush profile so the replacement does not exceed its transient capability during transfer.
Alternative Names
3607E 3607 E 3607-E Triconex 3607E Invensys Triconex 3607E Triconex 3607E Digital Output Module Triconex 3607E 48 VDC TMR DO Module
Technical notes
3607E must remain within its 44-80 VDC field range; verify the 1.25 A point fuses, non-commoned termination, and load inrush before energizing the replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which field-supply window belongs to 3607E?
The module is specified for 44–80 VDC operation around its nominal 48 VDC rating.
How does 3607E indicate a blown output fuse?
Voltage loopback identifies a commanded-state mismatch and activates the LOAD/FUSE field-alarm indication.
What machinery circuit is appropriate for 3607E?
Use it for supervised, non-commoned 48 VDC coils and relays within the one-amp continuous and five-amp transient limits.
Which condition evidence is supplied when quoting 3607E?
Apter Power confirms revision, physical condition, functional-test evidence, warranty, quantity and shipment requirement.
Why must the 3607E ETP fuse rating be retained?
The external panel uses a 1.25 A fast-acting fuse per point; changing it can alter circuit protection and fault response.
What site information helps match a 3607E replacement?
Send the ETP and cable references, point load list, steady and inrush current, field supply and hot-spare arrangement.