Features:
- Electronic pressure control: Converts an analog command into a repeatable pneumatic setpoint for a qualified air circuit.
- Feedback path: Returns a current monitor signal that can be compared with the commanded operating state.
- Exact connection identity: The full suffix fixes the port, thread and cable arrangement needed at the installed regulator.
ITV3050-044L is used between a clean compressed-air supply and equipment that needs controller-directed pressure rather than a fixed manual setting.
Its usefulness depends on the complete air path: adequate supply, free exhaust flow and a stable downstream volume must all be confirmed during commissioning.
The exact model remains present in SMC’s current web catalog; delivery is checked for the requested quantity and region.
Apter Power can help confirm the SMC ITV3050-044L ITV3000 Electro-Pneumatic Regulator, signal interface, air connections and cable arrangement before quotation.
SMC ITV3050-044L ITV3000 Electro-Pneumatic Regulator Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Signal source: Confirm the controller provides the required current-loop behavior and common reference.
- Monitor use: Decide whether the feedback output is trended, alarmed or reserved for commissioning evidence.
- Scaling record: Retain the command-to-pressure relationship with the machine documentation.
- Safe fallback: Define the required pneumatic state for loss of command or controller power.
- Supply quality: Use clean, dry air and prevent upstream pressure collapse during peak demand.
- Exhaust clearance: Keep the exhaust path open so downstream pressure can fall when commanded.
- Leak check: Test fittings and the controlled volume before blaming unstable regulation on electronics.
- Flow direction: Match supply, output and exhaust ports to the installed circuit.
- No-pressure case: Separate missing air, missing command and blocked flow before replacing the regulator.
- Slow response: Inspect downstream volume, restriction and exhaust routing under actual load.
- Signal mismatch: Compare the command, monitor output and independent pressure reference.
- Replacement record: Photograph the full code, connector direction and tube route before removal.
- Variable-force tooling: Adjusts actuator pressure between qualified recipes without manual knob changes.
- Pneumatic test stands: Establishes controller-selected pressure for repeatable test sequences.
- Air-blow control: Modulates supply pressure where process demand changes by product or step.
- Machine retrofit: Restores an installed ITV3000 analog pressure-control point with the same interfaces.