Open now · we reply within 2 working hours

Talk to our team

+86 15359408275

Call and you reach an account manager, not a queue.


What happens next?

  1. Email confirmationYou will get an email confirming that we have received your enquiry.
  2. Dedicated Account ManagerOne of our team will be in touch to confirm your part(s) specification and condition.
  3. Your quoteYou will receive a comprehensive quote tailored to your specific needs.

Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with ITV3050-044L

  • BMG2-012 Direct Mount Auto Switch Mounting Bracket
  • AS3201F-02-06SA AS Series Meter-Out Elbow Speed Controller with One-Touch Fitting
  • CXSM10-30 CXS Series Dual Rod Cylinder

All in stock · Add one and it is quoted together with the model, one shipping cost.

ITV3050-044L

SMC ITV3050-044L is an ITV3000 electro-pneumatic regulator that converts a 4–20 mA command into proportional compressed-air pressure with analog feedback.

In Stock Ships by Thursday, November 26 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for ITV3050-044L

ITV3050-044LSMC ITV3000 Electro-Pneumatic Regulator
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
SMC
Part Number
ITV3050-044L
Product Family
SMC
Product Type
ITV3000 Electro-Pneumatic Regulator
Stock
1
Tariff Code
Please confirm the destination before shipping
Country of origin
Japan
Place of shipment
Xiamen,Fujian,China

More information

Features:

  • Electronic pressure control: Converts an analog command into a repeatable pneumatic setpoint for a qualified air circuit.
  • Feedback path: Returns a current monitor signal that can be compared with the commanded operating state.
  • Exact connection identity: The full suffix fixes the port, thread and cable arrangement needed at the installed regulator.
ITV3050-044L is used between a clean compressed-air supply and equipment that needs controller-directed pressure rather than a fixed manual setting.

Its usefulness depends on the complete air path: adequate supply, free exhaust flow and a stable downstream volume must all be confirmed during commissioning.

The exact model remains present in SMC’s current web catalog; delivery is checked for the requested quantity and region.

Apter Power can help confirm the SMC ITV3050-044L ITV3000 Electro-Pneumatic Regulator, signal interface, air connections and cable arrangement before quotation.
SMC ITV3050-044L ITV3000 Electro-Pneumatic Regulator Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Signal source: Confirm the controller provides the required current-loop behavior and common reference.
  • Monitor use: Decide whether the feedback output is trended, alarmed or reserved for commissioning evidence.
  • Scaling record: Retain the command-to-pressure relationship with the machine documentation.
  • Safe fallback: Define the required pneumatic state for loss of command or controller power.
  • Supply quality: Use clean, dry air and prevent upstream pressure collapse during peak demand.
  • Exhaust clearance: Keep the exhaust path open so downstream pressure can fall when commanded.
  • Leak check: Test fittings and the controlled volume before blaming unstable regulation on electronics.
  • Flow direction: Match supply, output and exhaust ports to the installed circuit.
  • No-pressure case: Separate missing air, missing command and blocked flow before replacing the regulator.
  • Slow response: Inspect downstream volume, restriction and exhaust routing under actual load.
  • Signal mismatch: Compare the command, monitor output and independent pressure reference.
  • Replacement record: Photograph the full code, connector direction and tube route before removal.
  • Variable-force tooling: Adjusts actuator pressure between qualified recipes without manual knob changes.
  • Pneumatic test stands: Establishes controller-selected pressure for repeatable test sequences.
  • Air-blow control: Modulates supply pressure where process demand changes by product or step.
  • Machine retrofit: Restores an installed ITV3000 analog pressure-control point with the same interfaces.

Description

ITV3050-044L gives a controller an electronic way to set downstream air pressure, replacing repeated manual regulator adjustment in machines that change force or process conditions.

The complete order code of ITV3050-044L combines a current-command input, current monitor output, Rc half-inch ports and a right-angle three-metre cable, so purchasing must preserve more than the ITV3000 family name.

During replacement, ITV3050-044L should be commissioned against the real pneumatic load because supply quality, exhaust restriction and downstream leakage can change pressure behavior even when the electrical command is correct.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Leonia
Xiamen, ChinaAutomation spares

Bureau Veritas Audit Strengthens Trust for Global Buyers

A Bureau Veritas review checked Apter Power's business licence, registered address, office and selected export records, helping overseas buyers verify the company behind a quotation before ordering.

VerifiedBusiness identity checked
BV AuditCompany records reviewed
“ Trust starts with company details and trading records that buyers can verify. — Apter Power Team ”
Leonia · Xiamen, China · 2026
Read the full case study
May
Malaysia3500/22M

Malaysia Customer Collects Bently Nevada 3500/22-01-02-00 After On-Site Inspection

After equipment downtime, a Malaysian customer travelled to Xiamen to inspect and collect a Bently Nevada 3500/22-01-02-00. The unit could be tested and put into use the next day, helping shorten factory downtime and reduce associated losses.

5On-site checks
1 dayReady for testing
“ Apter responded quickly and had the right Bently Nevada module ready for us to inspect and collect. — Shah ”
May · Malaysia · October 2026
Read the full case study
May
ChinaBently Nevada

Bently Nevada Audit: Zero Discrepancies, USD 25,000 Order

A customer verified Bently Nevada accelerometers, cables and 3500/22M modules at Apter Power. Zero discrepancies led to a USD 25,000 order paid three hours later.

3 hrsOrder to payment
$25,000Follow-up order
“ Apter Power gave us the evidence to approve the expansion with confidence. — Customer procurement manager ”
May · China · 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

A PLC command changes but pressure from ITV3050-044L does not move. What should maintenance isolate first?

Compare the loop current at the regulator with the independent pressure reading, then check air supply and exhaust. That separates an electrical command problem from a pneumatic restriction.

Pressure from ITV3050-044L falls too slowly after a stop request. What installation issue is most important?

Inspect the exhaust path, downstream volume and any check valves or flow controls. Do not assume the regulator is faulty until trapped air and circuit restrictions are ruled out.

Purchasing is offered another ITV3000 for ITV3050-044L. Which differences can block a direct replacement?

The pressure code, command type, monitor output, thread, port size and cable orientation all matter. Require the complete order identity rather than a family-only match.

The monitor signal from ITV3050-044L disagrees with a pressure gauge. How should commissioning proceed?

Verify loop loading and scaling, then compare both signals through several stable commands. Stop release if the disagreement exceeds the process tolerance or changes unpredictably.

An actuator moves when ITV3050-044L is re-energized after service. What procedure should change?

Commission with motion isolated or safely restrained, begin from the defined low-pressure state and verify the controller startup command before reconnecting the load.

The air circuit downstream of ITV3050-044L leaks during a hold step. Should calibration be adjusted?

No. Repair leakage and confirm supply stability first. Calibration cannot compensate safely for a changing pneumatic load or a circuit that cannot retain the commanded condition.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat