Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Quotations and manuals for 6ES7153-2BA70-0XB0 are available through Apter Power, alongside system-matching assistance.

6ES7153-2BA70-0XB0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6ES7153-2BA70-0XB0 is an IM 153-2 OD interface module that connects ET 200M distributed I/O stations to PROFIBUS DP.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7153-2BA70-0XB0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7153-2BA70-0XB0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7153-2BA70-0XB0
  • Product Family:
    Siemens ET 200M
  • Product Type:
    IM 153-2 OD PROFIBUS Interface Module
  • Stock:
    1
  • Supply Voltage:
    24 V DC; 20.4–28.8 V DC
  • Current Consumption:
    650 mA
  • Power Loss:
    5.5 W
  • Voltage-Failure Buffering:
    5 ms
  • Backplane Supply:
    5 V DC; 1.5 A maximum
  • Local I/O Expansion:
    12 S7-300 modules maximum
  • Station Address Space:
    244 input bytes; 244 output bytes
  • Fieldbus Interface:
    PROFIBUS DP, RS485, 9-pin
  • Transmission Rate:
    Up to 12 Mbit/s; automatic detection
  • Station Address:
    1–125
  • Timestamp Resolution:
    1 ms with up to 8 modules; 10 ms with up to 12
  • Timestamp Signals:
    128 per station; 32 per slot maximum
  • Protection Rating:
    IP20
  • Operating Temperature:
    -25 to +60 °C horizontal; -25 to +40 °C vertical
  • Installation Altitude:
    3,000 m maximum
  • Isolation Test Voltage:
    500 V
  • Weight:
    0.6305 lbs (0.286 kg)
  • Estimated shipping dimensions:
    15.2×12.9×5.1cm
  • Tariff Code:
    85389091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Engineering DP Services Replacement Scope Applications

Features:

  • Redundant interface-module operation is supported.
  • Expanded HART auxiliary data can be transferred.
  • Isochronous operation is available.
The 6ES7153-2BA70-0XB0 interface supplies the station backplane separately from the fieldbus connection. Its PROFIBUS interface connects the distributed station to the master rather than acting as an individual analog channel.

High-channel-count modules are supported by 6ES7153-2BA70-0XB0, including 64-channel I/O modules. Module count and allocated input/output bytes remain separate station configuration limits.

Slave Initiative support on 6ES7153-2BA70-0XB0 is available for Drive ES and Switch ES. This service is distinct from the cyclic input/output exchange used by the connected station.

The Siemens 6ES7153-2BA70-0XB0 IM 153-2 OD PROFIBUS Interface Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7153-2BA70-0XB0 IM 153-2 OD PROFIBUS Interface Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Select the interface in the engineering tool

  • Hardware support: HSP 246 adds the interface to the relevant STEP 7 hardware catalog.
  • Catalog entry: In STEP 7 V5.5 SP4, the IM 153-2 OD entry is located under PROFIBUS DP and DP/PA Link.
  • Order number: The hardware-catalog information displays the full order number to distinguish the selected interface.
  • Other tools: GSD-based tools can configure the interface without using the same STEP 7 catalog workflow.

Coordinate station data and bus operation

  • SYNC: SYNC operation is supported for coordinated output updating.
  • FREEZE: FREEZE operation is supported for holding input data.
  • Transmission setup: The interface detects the PROFIBUS transmission rate automatically.
  • Station identity: The bus address identifies the interface as a PROFIBUS station and is separate from I/O byte allocation.

Distinguish replacement operation from a new configuration

  • Predecessor projects: Specified IM 153-2 predecessor configurations can continue without changing the STEP 7 project.
  • Functional selection: A replacement installation retains the functions of the configured predecessor rather than automatically selecting every new function.
  • IM 157 exception: Operation as the IM 157 in the identified redundant BM IM/IM configuration is excluded from this replacement scope.
  • New installation: A new project can select the IM 153-2 OD hardware entry instead of relying on a predecessor entry.

Two distributed-station arrangements

  • ET 200M: The interface connects an ET 200M station of S7-300 I/O modules to PROFIBUS DP.
  • DP/PA Link: The module is also used as the interface in a DP/PA Link arrangement.
  • Redundant station: Redundant interface operation is supported in the corresponding station configuration.
  • Outdoor variant: The OD version extends the operating-temperature range for these interface arrangements; it is not a weatherproof enclosure.
Description
The IM 153-2 OD interface, Siemens 6ES7153-2BA70-0XB0, connects an ET 200M distributed I/O station to PROFIBUS DP. Local S7-300 modules exchange their input and output data through the interface and the station backplane.

Timestamp organization on 6ES7153-2BA70-0XB0 depends on the station expansion. Up to eight modules support the 1 ms timestamp setting, while stations with up to twelve modules use the 10 ms setting. Message storage is organized into fifteen buffers with twenty messages each, separate from the cyclic I/O address space.

Direct data exchange on 6ES7153-2BA70-0XB0 has different publisher and subscriber scopes. All I/O modules can participate on the publisher side, whereas subscriber operation is limited to F-I/O modules. The two directions must not be treated as having identical module support.

Installation orientation changes the permitted upper ambient temperature for 6ES7153-2BA70-0XB0. Horizontal operation allows a higher limit than vertical operation, while both orientations share the same lower operating limit. The outdoor variant designation does not remove the enclosure requirements associated with IP20 protection.
Alternative Names
6ES71532BA700XB0 6ES7153 2BA70 0XB0 6ES7 153-2BA70-0XB0 Siemens 6ES7153-2BA70-0XB0 6ES7153-2BA70-0XB0 IM 153-2 OD PROFIBUS Interface Module 6ES7153-2BA7O-OXBO 6ES7I53-2BA70-0XB0 IM 153-2 OD PROFIBUS Interface Module 6ES7153-2BA70-0XB0
Technical notes
Siemens 6ES7153-2BA70-0XB0 supports redundant interface operation, timestamping and expanded HART auxiliary data in ET 200M and DP/PA Link configurations.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Where can 6ES7153-2BA70-0XB0 be selected if it is missing from the STEP 7 catalog?
Install the applicable HSP 246 support for 6ES7153-2BA70-0XB0; STEP 7 V5.5 SP4 lists IM 153-2 OD under PROFIBUS DP > DP/PA Link.
For a GSD-configured DP/PA Link, which selection is specified for 6ES7153-2BA70-0XB0?
The DP/PA Link instructions use the predecessor 6ES7153-2BA82-0XB0 selection when configuring 6ES7153-2BA70-0XB0 with a GSD-based tool. This is a configuration instruction, not a change to the supplied part number.
Is 6ES7153-2BA70-0XB0 interchangeable with an IM 157 in every redundant arrangement?
No. The IM 157 6ES7157-0AA81-0XA0 arrangement using redundant BM IM/IM 6ES7195-7HE80-0XA0 is excluded from the replacement scope of 6ES7153-2BA70-0XB0.
Does a twelve-module station preserve the fastest timestamp setting of 6ES7153-2BA70-0XB0?
A twelve-module configuration uses the 10 ms timestamp setting on 6ES7153-2BA70-0XB0; the 1 ms setting is associated with no more than eight modules.
What happens if 6ES7153-2BA70-0XB0 starts with its address switches at zero?
Address zero at power-on initiates restoration of default retentive configuration in 6ES7153-2BA70-0XB0. BF1 flashes during this sequence, so this setting is not an ordinary operating station address.