Features:
- The CPU 318-2 DP combines S7-300 program processing with two configurable communication interfaces.
- Code and data receive equal work-memory allocations inside the 512 KB total capacity.
- Distributed I/O can be managed as a DP master or linked to another controller as a DP slave.
The processor scans the user program and updates the rack process image while communication jobs use their assigned interfaces.
Memory-card contents can supply the load image, whereas executable code and current values move through separate working areas.
Rack expansion retains the S7-300 module layout, with each configured rack limited to eight module positions.
The Siemens 6ES7318-2AJ00-0AB0 SIMATIC S7-300 CPU 318-2 DP may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7318-2AJ00-0AB0 SIMATIC S7-300 CPU 318-2 DP Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
How the communication roles divide
- MPI Path: Programming devices and operator stations can share the multipoint interface for engineering and control access.
- DP Master: The second interface initiates cyclic exchange with configured distributed-I/O slaves.
- DP Slave: Slave mode exposes assigned input and output areas to a higher-level DP master.
- Direct Data: Configured direct communication transfers selected I/O data between participating stations without user-block polling.
Where program information is held
- Code Space: Program blocks execute from the dedicated half of the work-memory allocation.
- Data Space: Current process and block data occupy the independent data-memory half.
- Load Image: Integrated and removable load memory retain blocks before they are copied for execution.
- Retentive Areas: Configured flags, timers, counters and data blocks determine what survives a restart.
Central and expansion rack arrangement
- Central Rack: The CPU occupies the controller rack and exchanges the process image with adjacent S7-300 modules.
- Expansion Limit: A complete configuration can extend across four racks when interface modules are included.
- Module Limit: Each rack accepts up to eight configured module positions.
- Address Assignment: Slot placement and hardware configuration determine the I/O addresses presented to the program.
Locating a controller or network stop
- Diagnostic Buffer: Time-ordered events distinguish startup, programming and communication conditions.
- Module Events: Rack diagnostics identify an inaccessible or faulted configured module.
- DP Events: Master diagnostics show which distributed station no longer matches or responds to the configuration.
- Status Blocks: System information can be read by the user program when a diagnostic reaction must be handled in logic.