Features:
- The panel control combines CNC, PLC, HMI and communication tasks.
- Two DRIVE-CLiQ ports connect the controller to SINAMICS drive components.
- PROFIBUS DP carries distributed machine-I/O traffic on a separate fieldbus.
The CNC kernel interpolates the programmed tool path while the PLC handles machine sequencing.
Drive commands and feedback travel through DRIVE-CLiQ rather than the general plant Ethernet connection.
The operator-facing section and enclosure-facing interfaces have different protection boundaries.
The Siemens 6FC5370-0AA00-2BA0 SINUMERIK 802D sl G/N Plus Operator Panel Control may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6FC5370-0AA00-2BA0 SINUMERIK 802D sl Control Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Relating CNC interpolation to drive execution
- CNC kernel: The control calculates coordinated motion for the configured NC axes.
- Spindle paths: Dedicated spindle functions remain within the selected axis package.
- DRIVE-CLiQ: Command and feedback telegrams connect the control to SINAMICS components.
- PLC coordination: Machine interlocks and auxiliary sequences run beside the CNC tasks.
Keeping drive, fieldbus and service traffic on the correct connectors
- Ethernet: The RJ45 interface serves plant-network and engineering communication.
- PROFIBUS DP: The DP master exchanges process data with distributed machine devices.
- USB: Local media supports defined transfer and service operations.
- RS232: The serial interface provides an additional commissioning route.
Checking the control limits before restoring a machine archive
- Controlled axes: The execution coordinates up to six configured axes in total.
- NC allocation: No more than five axes belong to the NC path configuration.
- Spindle allocation: Up to two spindles can be included within the documented limits.
- PLC axis: One axis can be assigned to the PLC function.
Preserving the front and rear installation boundaries
- Front face: The operator-facing surface reaches the documented IP65 protection.
- Rear area: Connectors and electronics behind the panel remain IP00.
- Supply wiring: The 24 V feed enters at the dedicated power connector.
- Cabinet layout: Rear depth, ventilation and cable bend radii must remain accessible.