Features:
- Reverse-mount eddy-current sensing for inaccessible front-side locations.
- Two calibrated displacement ranges with matched voltage or current sensitivity.
- IP68 stainless-steel probe construction for severe machinery service.
The current ordering configuration is TQ412 111-412-000-013, the base reference for a reverse-mount TQ412 probe.
The sensor detects shaft position and vibration without contact when used in the correct calibrated measurement chain.
Verify suffix options, access direction, thread, cable protection and total system length before exchange.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter TQ412 111-412-000-013:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Vibro-meter TQ412 S3960 111-412-000-013 Eddy-Current Proximity Transducer Specs
General
- Manufacturer Vibro-meter
- Model TQ412 S3960 111-412-000-013
- Condition New Original ready stock
- Product Family
GSI124 244-124-000-022,EA402 913-402-000-013,GSI130 244-130-000-204
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not
included with this equipment unless listed in the above stock item description. All prices are
shown in USD.
- Supports reverse-mounted shaft vibration measurement in confined bearing housings.
- Measures axial movement or machine clearances on compatible conductive targets.
- Feeds calibrated machinery-protection channels for turbines, compressors and generators.
- Works with the EA402 extension-cable configuration specified by the ordering code.
- Requires an IQS900 conditioner calibrated for the selected range and total cable length.
- Must use target-material scaling consistent with the documented AISI 4140 reference.
- Supports static gap verification to confirm correct probe position during commissioning.
- Allows dynamic signal checks through the connected conditioner and monitoring channel.
- Requires investigation of cable, connector and target conditions before declaring a probe fault.