Vibro-Meter VM600 IOC16T 200-565-000-013 is the rear input/output card paired with a CMC16 condition monitoring processor. It terminates sixteen monitoring signal paths in legacy VM600 CMS racks.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for VM600 IOC16T 200-565-000-013
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for VM600 IOC16T 200-565-000-013

  • Manufacturer:
    Vibro-Meter
  • Part Number:
    VM600 IOC16T 200-565-000-013
  • Product Family:
    VM600 CMC16 / IOC16T Condition Monitoring System
  • Product Type:
    Condition Monitoring Input/Output Card
  • Stock:
    1
  • Companion Front Card:
    CMC16
  • Monitoring Channels:
    16 field-signal paths
  • Tachometer Paths:
    Up to 4 through CMC16 allocation
  • System Architecture:
    Legacy VM600 CMS
  • Rack Position:
    Rear I/O position paired with CMC16
  • Signal Processing:
    Performed by companion CMC16
  • Data Functions:
    Supports CMC16 trend and spectral acquisition
  • Interface Role:
    Sensor and auxiliary signal termination
  • Card Format:
    6U rear rack card
  • Dimensions:
    262 x 20 x 125 mm
  • Mass:
    Approximately 0.25 kg
  • Upgrade Pair:
    XMV16 with XIO16T
  • Lifecycle:
    Legacy CMC16/IOC16T platform discontinued
  • Replacement Scope:
    Front and rear cards reviewed together
  • Configuration Control:
    Back up monitoring database before change
  • Commissioning Check:
    Verify channel map, speed references and communications
  • Weight:
    0.551 lbs (0.25 kg)
  • Estimated shipping dimensions:
    2 x 12.5 x 26.1 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Switzerland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Compatibility Installation & Integration Upgrade Planning

Features:

  • Rear input/output interface for a legacy sixteen-channel CMC16 processor.
  • Field-signal termination for dynamic, speed and auxiliary monitoring paths.
  • Coordinated front-and-rear architecture within the VM600 condition-monitoring rack.
The current ordering configuration is VM600 IOC16T 200-565-000-013, the rear card paired with a legacy CMC16.

It routes field signals to the front processor, which performs conversion, spectral processing and trend generation.

Preserve terminal drawings and the monitoring database before pair replacement or XMV16/XIO16T migration.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter VM600 IOC16T 200-565-000-013:Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Terminates machinery vibration and speed-reference signals for CMC16 monitoring channels.
  • Supports legacy VM600 spectral, trend and transient data-acquisition projects.
  • Provides the rear interface used during maintenance and monitoring-system migration planning.
  • Pairs with the documented CMC16 front card in the corresponding VM600 rack slot.
  • Requires channel assignments and terminal wiring to match the preserved project database.
  • Migrates as part of an XMV16/XIO16T system conversion rather than an isolated rear-card swap.
  • Installs in the rear position directly associated with the CMC16 front module.
  • Connects field wiring through the documented VM600 terminal arrangement.
  • Requires verification of sensor, tachometer and communications paths after installation.
  • Backs up the complete monitoring configuration before legacy hardware is removed.
  • Reviews rack, cabling, software and host interfaces for XMV16/XIO16T migration.
  • Plans commissioning tests that preserve channel identity and historical measurement continuity.
Description
VM600 IOC16T 200-565-000-013 is a 6U rear interface card designed to pair with the CMC16 and route sixteen field-signal paths, including the channels allocated for speed references.

It provides the sensor and auxiliary-signal termination needed by legacy VM600 condition monitoring systems while the companion CMC16 performs acquisition, processing and diagnostics.

Replace the front and rear cards as a verified pair and back up the monitoring project first. Check connector assignments, channel mapping, speed inputs and communications before returning the rack to service.
Alternative Names
Vibro-Meter VM600 IOC16T 200-565-000-013 VM600 IOC16T 200 565 000 013 VM600-IOC16T-200-565-000-013 200565000013 Vibro-Meter condition monitoring I/O 200-565-000-013 IOC16T rear card for CMC16 VM600 legacy CMS interface card IOC16T sixteen-channel signal termination
Technical notes
VM600 IOC16T 200-565-000-013 must be evaluated with its CMC16 front card; preserve wiring records and database backups before pair replacement or XIO16T migration.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why must VM600 IOC16T 200-565-000-013 be assessed with a CMC16?
It is the rear I/O member of the CMC16/IOC16T pair, so signal paths and compatibility depend on both cards.
Which field signals reach VM600 IOC16T 200-565-000-013?
The rear interface terminates the dynamic, speed-reference and auxiliary connections assigned to the paired condition-monitoring channels.
How is VM600 IOC16T 200-565-000-013 used in a VM600 rack?
It occupies the rear I/O position corresponding to the CMC16 front card and routes signals without performing spectra itself.
Can Apter Power source VM600 IOC16T 200-565-000-013 as part of a verified CMC16/IOC16T pair?
Provide both card numbers, rack slot, terminal drawings, condition and quantity so the legacy pair can be checked.
What changes are involved when replacing VM600 IOC16T 200-565-000-013 with XIO16T?
The XMV16/XIO16T architecture can require front and rear hardware, software, wiring and database migration.
What should be sent with a VM600 IOC16T 200-565-000-013 documentation inquiry?
Provide the CMC16 number, rack slot, terminal drawings, software version and quantity for accurate matching.