Features:
- Supplies up to 330 W across +5 VDC and ±12 VDC rack rails.
- Accepts 48 VDC according to the selected input version.
- Maintains low ripple with specified line and load regulation.
The exact supply configuration is 200-582-300-013, identified for 48 VDC input service.
The module occupies the dedicated RPS6U rack position and distributes three regulated rails through the VM600 backplane.
Confirm the 48 VDC input label and rear-panel wiring; other RPS6U DC variants use different nominal voltage ranges.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter 200-582-300-013:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Powers a VM600 rack containing machinery-protection, communications and relay cards.
- Supports single-supply installations or approved redundant rack arrangements.
- Provides regulated low-voltage rails for centralized turbine and rotating-equipment monitoring.
- This configuration is identified for the 48 VDC member of the earlier RPS6U range.
- Rack wiring must remain within the input range printed for the installed supply and rear panel.
- Input polarity and protective earth should be verified before seating the power module.
- The supply delivers +5 VDC, +12 VDC and -12 VDC rails through the VM600 backplane.
- Combined output power is limited to 330 W across the three regulated rails.
- Rack load calculations must include every monitoring, relay and communications card.
- Cooling airflow around the 6U supply and rear input panel must remain unobstructed.
- A redundant supply arrangement requires the correct rack jumpers and independent input design.
- Inspect connector heating and DC-source stability during commissioning.