Features:
- Supplies up to 330 W across +5 VDC and ±12 VDC rack rails.
- Accepts 115/230 VAC or 220 VDC according to the selected input version.
- Maintains low ripple with specified line and load regulation.
The exact supply configuration is 200-582-500-122, identified for 115/230 VAC or 220 VDC input service.
The module occupies the dedicated RPS6U rack position and distributes three regulated rails through the VM600 backplane.
The 02-series front panel differs from earlier RPS6U versions; verify rack generation, rear panel and input labelling before replacement.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter 200-582-500-122:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Powers a VM600 rack containing machinery-protection, communications and relay cards.
- Supports single-supply installations or approved redundant rack arrangements.
- Provides regulated low-voltage rails for centralized turbine and rotating-equipment monitoring.
- Autoranging AC circuitry covers both low-line and high-line mains windows.
- Three regulated outputs support VM600Mk2 or VM600 rack electronics up to the combined power limit.
- The later front design uses a common IN label for AC- and DC-input supply versions.
- Front indicators show external input availability and regulated output status.
- Power-supply check circuitry can be incorporated into the ABE04x rack supervision scheme.
- Unusual rail voltage or repeated input loss should be investigated before returning the rack to service.
- The rack and rear input panel must match the selected mains architecture.
- Input protection and earth bonding must follow the VM600 hardware and site electrical requirements.
- The complete system approval depends on the rack, supply, rear panel and installed monitoring cards.