Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle

    Superseded
    Superseded in September 2010
    Engineering replacement: ControlMaster CM10

C100/0100/STD

/ 4.9
1001 reviews | Need a Specific Revision?
ABB C100/0100/STD is a COMMANDER 100 universal single-loop process controller used for sensor-based PID control, alarms and compact ramp/soak sequences.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for C100/0100/STD
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for C100/0100/STD

  • Manufacturer:
    ABB
  • Part Number:
    C100/0100/STD
  • Product Family:
    ABB Commander
  • Product Type:
    COMMANDER 100 Universal Process Controller
  • Stock:
    1
  • Control Modes:
    P, PI or PID
  • Additional Relay Option:
    /01
  • Input Types:
    Thermocouple, Pt100, mV, current or DC voltage
  • Thermocouple Types:
    B, E, J, K, N, R, S or T
  • Input Sampling Time:
    250 ms per channel
  • Current Input Impedance:
    100 Ω
  • mV and Voltage Input Impedance:
    >10 MΩ
  • Transmitter Power Supply:
    24 V DC at 30 mA
  • Current Output:
    4–20 mA; maximum load 750 Ω
  • Logic Output:
    18 V at 20 mA; minimum load 400 Ω
  • Relay Outputs:
    Two SPDT relays with /01 option
  • Alarms:
    Two
  • Ramp/Soak Program:
    Four segments
  • Power Supply:
    85–265 V AC, 50/60 Hz
  • Power Consumption:
    Less than 6 VA
  • Operating Temperature:
    0 to +55 °C
  • Operating Humidity:
    5 to 95% RH, non-condensing
  • Front Protection:
    IP65/NEMA 3
  • Dimensions:
    4.8 × 9.6 × 12.5 cm
  • Auto-Tuning:
    One-shot auto-tune
  • Tariff Code:
    9032899099
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Setup Control Output Ramp and Alarms Application
  • Universal input for thermocouple, Pt100 and standard analog signals
  • Configurable P, PI or PID control with current or logic output
  • Two relays and a four-segment ramp/soak sequence in the /01 build

C100/0100/STD is an ABB COMMANDER 100 controller for compact single-loop process control.

Its universal input, control algorithms, alarms and ramp/soak function support sensor-based control from one panel instrument.

Before installation or replacement, verify the input type, 85–265 V AC supply, output mode, relay assignments, tuning values, terminal wiring and saved program.

Availability, condition, price, and shipping time for C100/0100/STD are confirmed during quotation.

ABB C100/0100/STD COMMANDER 100 Controller Manuals, Product Family, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Select the thermocouple, Pt100, millivolt, current or voltage input before calibration
  • Match thermocouple linearization and cold-junction compensation to the installed sensor
  • Use the internal transmitter supply only within its documented voltage and current limits
  • Configure P, PI or PID behavior for the response required by the controlled process
  • Assign the current or logic output to the selected control or retransmission function
  • Confirm relay assignments and external load ratings before energizing the output circuits
  • Program up to four ramp or soak segments for staged setpoint operation
  • Set alarm type, threshold and hysteresis independently for the required process response
  • Verify the configured end action before starting an unattended program
  • Single-loop temperature control in ovens, furnaces and compact heating equipment
  • Pressure, flow or level control in packaged process machinery
  • Four-segment ramp/soak control for small batch heating processes
Description
C100/0100/STD is an ABB COMMANDER 100 universal single-loop process controller with an additional relay and an 85–265 V AC supply.

The controller accepts thermocouple, Pt100 and standard analog signals and provides configurable P, PI or PID control, alarms, current or logic output and four-segment ramp/soak operation.

Before installation or replacement, confirm the complete C100/0100/STD order code, sensor input, power supply, relay assignments, output type, tuning values, alarms, terminal wiring and stored program.
Alternative Names
C100/0100/STD C100 / 01 0 0 / STD ABB C100/0100/STD ABB Commander C100/0100/STD COMMANDER 100 C100/0100/STD
Technical notes
C100/0100/STD uses 85–265 V AC power and the /01 additional relay. Verify input, output, alarm, ramp/soak and terminal assignments before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which sensor inputs can ABB C100/0100/STD accept?
ABB C100/0100/STD can be configured for supported thermocouples, Pt100 resistance thermometers, millivolt, current or DC voltage signals. The selected input type and terminal wiring must match the installed sensor.
How does the /01 relay option affect ABB C100/0100/STD integration?
The /01 code provides the additional relay arrangement documented for ABB C100/0100/STD. Confirm each relay assignment, contact rating and external load circuit before transferring the existing configuration.
Can ABB C100/0100/STD use a 4–20 mA control output?
Yes. ABB C100/0100/STD supports a 4–20 mA current output when that output is configured for control or retransmission and the connected load remains within the documented limit.
How is ramp/soak operation configured on ABB C100/0100/STD?
ABB C100/0100/STD supports a four-segment ramp/soak sequence. Enter the target levels and segment times, then confirm the start, hold and end behavior required by the process.
What must be preserved when replacing ABB C100/0100/STD?
Record the complete order code, input type, output and relay assignments, alarm values, tuning constants, ramp/soak settings and terminal wiring before removing ABB C100/0100/STD.
Why might ABB C100/0100/STD fail to control after a sensor change?
A mismatched input type, thermocouple linearization, Pt100 connection, engineering range or control action can prevent correct operation. Recheck the input configuration and recalibrate ABB C100/0100/STD for the installed sensor.
What should be checked if an ABB C100/0100/STD relay does not switch the load?
Verify the configured relay function, alarm or control state, contact wiring, external supply, load current and interlocks. Test the field circuit separately before concluding that the ABB C100/0100/STD relay has failed.