Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power reviews software readiness, exact cabinet identity, condition, and upgrade scope before quotation.

3HAC025527-001

/ 4.9
1001 reviews | Need a Specific Revision?
ABB 3HAC025527-001 is the DSQC639 computer cabinet recorded for IRC5 service, with a RobotWare-gated upgrade path rather than an unrestricted computer substitution.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 3HAC025527-001
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3HAC025527-001

  • Manufacturer:
    ABB
  • Part Number:
    3HAC025527-001
  • Product Family:
    ABB Robots
  • Product Type:
    Computer Cabinet DSQC639
  • Stock:
    1
  • Controller platform:
    IRC5
  • Computer designation:
    DSQC639
  • ABB upgrade kit:
    3HAC079227-001
  • Upgrade requirement:
    RobotWare 5.30
  • Tariff Code:
    84799070
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals RW5.30 Upgrade Cabinet Boundary Outage Decision Product Applications

Features:

  • Cabinet-level identity: ABB calls the article a DSQC639 computer cabinet
  • Upgrade direction: the recorded kit is 3HAC079227-001
  • Software gate: RobotWare 5.30 is required for the upgrade path
ABB 3HAC025527-001 is differentiated by its computer-cabinet scope within the IRC5 service structure.

The RobotWare requirement turns replacement into a software-and-hardware decision rather than a connector-only task.

A complete pre-outage record lets procurement and engineering decide whether to retain the legacy cabinet or execute the documented upgrade.
Apter Power can review 3HAC025527-001 labels, RobotWare evidence, upgrade-kit scope, and available condition documentation before quotation.
ABB 3HAC025527-001 Computer Cabinet DSQC639 Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • ABB route: upgrade kit 3HAC079227-001 is specified.
  • Software threshold: the controller requires RobotWare 5.30.
  • Decision timing: establish software eligibility before the shutdown.
  • Recovery control: keep a verified pre-upgrade system backup.
  • Published scope: ABB identifies a computer cabinet, not a loose board.
  • Variant control: do not merge the -001 record with other DSQC639 assemblies.
  • Installed evidence: the complete cabinet label governs selection.
  • Connection record: document every external and option-hardware interface.
  • Legacy spare: retain the existing architecture when upgrade prerequisites are unmet.
  • Upgrade project: include software, licenses, hardware, and restoration work.
  • Acceptance baseline: compare boot, options, networks, and safety functions.
  • Rollback: preserve the original archive and removed cabinet until validation ends.
  • IRC5 cabinet recovery: restore a DSQC639-based controller from a documented baseline.
  • RobotWare-gated modernization: evaluate the ABB upgrade kit before hardware work.
  • Shutdown planning: align computer hardware, software, licenses, and commissioning resources.
  • Legacy spare control: keep cabinet-level articles separate from loose computer components.
Description
At cabinet level, 3HAC025527-001 is the DSQC639 computer cabinet, giving maintenance teams an object-level replacement scope rather than an unspecified processor-board request.

Upgrade kit 3HAC079227-001 provides the migration path from 3HAC025527-001, with RobotWare 5.30 as the software prerequisite. The result is a controlled migration rather than a loose board exchange.
Alternative Names
3HAC025527001 DSQC639 computer cabinet ABB IRC5 computer cabinet ABB 3HAC079227-001 source cabinet
Technical notes
3HAC025527-001 is linked by ABB to upgrade kit 3HAC079227-001 with RobotWare 5.30 required. If the installed IRC5 release or system backup cannot support that boundary, an outage can stall after hardware removal; verify the software level, licenses, cabinet assembly, options, and recoverable archive before choosing the upgrade route.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why must RobotWare be checked before choosing the upgrade route for 3HAC025527-001?
ABB requires RobotWare 5.30 for the recorded 3HAC079227-001 upgrade kit. If the installed system cannot meet that threshold, complete the software and backup plan before removing the DSQC639 cabinet.
How can a buyer distinguish 3HAC025527-001 from another DSQC639 listing?
Use the complete ABB article number and confirm that the required scope is the computer cabinet. A shared DSQC639 designation does not make a main computer, computer unit, and cabinet-level spare equivalent.
What should be tested after 3HAC025527-001 is restored from a backup?
Confirm a clean boot, expected option recognition, controller identity, field-network communication, I/O status, safety functions, and program integrity. Compare each result with the captured pre-outage baseline before returning to production.
When should an engineer stop an upgrade involving 3HAC025527-001?
Stop before hardware removal if the RobotWare level is below the documented requirement, the backup is unreadable, license evidence is missing, or the installed option and connector inventory is incomplete. Resolve those gaps first.
Why can a controller powered through 3HAC025527-001 still lose field communications?
Cabinet power only proves part of the restoration. Compare installed option hardware, cable positions, saved network settings, licenses, and detected boards with the original record before editing field-device configurations.
Which details make an urgent 3HAC025527-001 quotation technically useful?
Provide the full cabinet label, current RobotWare release, controller type, validated backup status, installed options, fault condition, required scope, quantity, and outage date. These details determine whether a legacy cabinet or upgrade project is appropriate.