Open now · we reply within 2 working hours

Talk to our team

+86 15359408275

Call and you reach an account manager, not a queue.


What happens next?

  1. Email confirmationYou will get an email confirming that we have received your enquiry.
  2. Dedicated Account ManagerOne of our team will be in touch to confirm your part(s) specification and condition.
  3. Your quoteYou will receive a comprehensive quote tailored to your specific needs.

Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with IC697MDL350

  • IC697MDL740 24/48 VDC 2 A 16-Point Output Module
  • IC697CPX935 Series 90-70 96 MHz CPU with 1 Mbyte fast memory
  • IC697MDL653 24 VDC Positive/Negative Logic 32-Point Input Module

All in stock · Add one and it is quoted together with the model, one shipping cost.

IC697MDL350

GE IC697MDL350 switches thirty-two 120 VAC loads in four isolated, fused groups designed for contactors, solenoids, indicators and other inrush-bearing devices.

In Stock Ships by Tuesday, November 24 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for IC697MDL350

IC697MDL350General Electric 120 VAC 0.5 A 32-Point Output Module
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
General Electric
Part Number
IC697MDL350
Product Family
GE 90-70 Series PLC
Product Type
120 VAC 0.5 A 32-Point Output Module
Stock
1
Tariff Code
8538900000
Country of origin
USA
Place of shipment
Xiamen, Fujian, China

More information

  • Four isolated banks of eight 120 VAC outputs
  • Five-amp fast-acting fuse for each output bank
  • High one-cycle inrush capability for suitable loads

IC697MDL350 is a Series 90-70 output module that switches thirty-two 120 VAC field loads through four electrically isolated banks of eight channels.

Each point can control compatible contactors, solenoids, indicators, and other AC devices within the documented current limits. Its one-cycle inrush capability supports suitable loads with higher starting current when repetition and bank loading remain controlled.

Each output bank has a separate field feed and five-amp fast-acting fuse, helping contain a circuit problem to eight channels. Before replacement, verify the complete hardware suffix, bank current, fuse type, load inrush, terminal assignments, slot keying, and configured fault-state behavior.

Availability, condition, price, and shipping time for IC697MDL350 are confirmed during quotation.

General Electric IC697MDL350 120 VAC 0.5 A 32-Point Output Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Calculate steady and inrush current for each device
  • Keep each bank within the two-ampere limit
  • Install suppression at inductive loads
  • Use only the specified five-ampere fast-acting fuse
  • Investigate a fuse operation before replacement
  • Verify each group has the correct field feed
  • Record the programmed fault-mode selection
  • Prove outputs-off or hold-last-state behavior
  • Confirm interlocks before returning production
  • AC solenoid and contactor control
  • Indicator and pilot-device switching
  • High-density Series 90-70 discrete output replacement

Description

IC697MDL350 divides thirty-two triac output points into four isolated banks. Each eight-point bank has its own AC feed and a replaceable 5 A fast-acting group fuse.

A point can carry 0.5 A continuously while the group is limited to 2 A. The 10 A one-cycle inrush rating supports suitable inductive or incandescent loads when duty cycle and enclosure temperature are considered.

The programmed fault response can either preserve the last output state or turn the outputs off. That choice must match the machine's safe-state design before a replacement is accepted.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Yuki
USA11 Emerson DeltaV models

11 Emerson DeltaV Models Secured and Inspected for an American Natural Gas Project

See how Apter Power secured 11 new and unused Emerson DeltaV models, supported independent powered inspection and delivered the order for an American natural gas project.

11DeltaV models secured
6 daysFull order prepared
“ Apter secured all our DeltaV models and supported independent inspection before we paid the balance. — Mohanad ”
Yuki · USA · May 2026
Read the full case study
Jim
Xiamen, ChinaBently Nevada

A Practical Bently Nevada 3500 Plan to Cut Factory Downtime

A practical factory deployment plan connecting 3300 XL proximity probes, a Bently Nevada 3500 rack, DCS/PLC systems and System 1 software to detect rotating-equipment risks earlier and support predictive maintenance.

3 LayersSensors to diagnostics
4 StepsPlanning to maintenance
“ A 3500 project starts with understanding machinery risks and maintenance needs. — Jim ”
Jim · Xiamen, China · 2026
Read the full case study
Leonia
IndiaSiemens SIMATIC S7-400 PS 407 · 6ES7407-0DA01-0AA0

Siemens PS 407 Verified for an Indian Textile Plant

An Indian textile manufacturer asked Apter Power to verify Siemens SIMATIC S7-400 PS 407 module 6ES7407-0DA01-0AA0 by complete catalogue number, visible condition and packaging evidence before the next supply decision.

24/7Textile plant support
100%Inspected for Original & New product
“ Apter made our first overseas purchase of Siemens S7-1200 spares straightforward, with clear model confirmation and delivery arrangements. — Singh ”
Leonia · India · 9 October 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

Can GE IC697MDL350 start contactors directly?

It can operate compatible loads and will pick up many documented contactors, but coil steady current, one-cycle inrush, switching frequency and required suppression must all be checked.

Why can one GE IC697MDL350 group stop while the other outputs work?

Each bank has its own 5 A fuse and field feed. Check the group's fuse indicator, AC supply, neutral, total current and terminal-board contact before replacing the module.

How should GE IC697MDL350 group loading be calculated?

Limit every point to 0.5 A and every eight-point bank to 2 A, then apply temperature and duty-cycle considerations so simultaneous loads do not exceed the thermal envelope.

What fault response should be selected for GE IC697MDL350?

Choose hold-last-state or outputs-off only from the machine risk assessment. Confirm the programmed selection and prove the safe response during a controlled CPU or communications stop.

Does GE IC697MDL350 need external load suppression?

Yes for inductive devices. The module's switching capability does not replace suppression at contactor or solenoid coils, which reduces electrical noise and stress on the output stage.

What revision-related insulation check applies to GE IC697MDL350?

GE documentation identifies Version F as the threshold in the high-voltage insulating-strip note. Inspect earlier hardware when it sits immediately right of a metal faceplate.

What should be tested after fitting GE IC697MDL350?

Command every output, verify the field voltage under load, check all four fuse indicators, measure grouped current and confirm the configured fault-mode action before production release.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

IC697MDL740
GE IC697MDL740 drives sixteen 24/48 VDC loads in four isolated four-point groups, with 2 A point capacity and group-level fuse monitoring.
In stock
IC697CPX935
IC697CPX935 is a fast-memory GE Fanuc Series 90-70 controller CPU built for single-slot installation, with three onboard serial interfaces.
In stock
IC697MDL653
GE IC697MDL653 collects thirty-two 24 VDC signals through four isolated groups and supports either positive-logic or negative-logic field-device arrangements.
In stock
IC697CHS790
Nine module slots and a dedicated power-supply position let General Electric IC697CHS790 organize Series 90-70 IC697 PLC hardware in a rear-mounted rack.
In stock
IC697CHS791
General Electric IC697CHS791 is a nine-slot front-mount Series 90-70 standard rack that presents installed modules for rack-side access and servicing.
In stock
IC697MEM715
GE IC697MEM715 is a 128 Kbyte CMOS daughterboard that expands supported CPU771, CPU772 or PCM711 assemblies without occupying another rack slot.
In stock
IC697ACC724
Three parallel fans in the General Electric IC697ACC724 rack fan assembly move filtered cooling air upward through supported Series 90-70 and listed IC698 racks.
In stock
IC697CPU711
General Electric IC697CPU711 is a legacy Series 90-70 rack CPU identifier supported through exact nameplate, rack and project-record matching.
In stock
IC697MDL240
GE IC697MDL240 accepts sixteen independently isolated 120 VAC field inputs, allowing separate points to monitor circuits that do not share one neutral or phase.
In stock
IC697MDL350
GE IC697MDL350 switches thirty-two 120 VAC loads in four isolated, fused groups designed for contactors, solenoids, indicators and other inrush-bearing devices.