General Electric DS200PCCAG9ACB is a G9 regenerative PCCA that connects drive control circuitry to an SCR power bridge.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for DS200PCCAG9ACB
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for DS200PCCAG9ACB

  • Manufacturer:
    General Electric
  • Part Number:
    DS200PCCAG9ACB
  • Product Family:
    GE Mark V/VI Driver Board
  • Product Type:
    Power Connect Card Assembly
  • Stock:
    1
  • Group:
    G9 regenerative configuration
  • Armature Voltage:
    240–630 V
  • Maximum Accepted AC Voltage:
    ≤ 600 V rms
  • Compatible Frames:
    J and M
  • Power Board:
    Compatible SDCI board
  • Snubber Type:
    DC voltage snubbers
  • Protection Hardware:
    Leg fuse and leg reactor
  • Bus Transformer:
    Separate or common arrangement
  • Dimensions:
    28.0 × 21.4 × 2.3 cm
  • Weight:
    0.4 kg
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Regeneration Protection Integration Application
  • G9 regenerative PCCA for 240–630 V armature systems
  • J and M frame support with a compatible SDCI board
  • DC snubbers plus leg-fuse and leg-reactor provisions

DS200PCCAG9ACB is a General Electric Power Connect Card Assembly designed for regenerative GE DC2000/Mark V drive assemblies.

It routes power and gate-control connections between the drive, the SCR bridge, and associated transformer and protection components in a regenerative configuration.

Before installation or replacement, verify G9 regenerative duty, 240–630 V armature class, J/M frame, SDCI board, DC snubbers, fuse and reactor arrangement, transformer configuration, and jumper settings.

Availability, condition, price, and shipping time for DS200PCCAG9ACB are confirmed during quotation.

General Electric DS200PCCAG9ACB Power Connect Card Assembly Manuals, Product Family, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • G9 regenerative configuration
  • 240–630 V armature service
  • Maximum accepted AC voltage is 600 V rms
  • DC voltage snubbers
  • Leg fuse in the protected power path
  • Leg reactor in the installed drive arrangement
  • J and M frame compatibility
  • Works with the associated SDCI power board
  • Supports separate or common bus transformers
  • Regenerative J-frame DC2000 drives
  • Regenerative M-frame DC2000 drives
  • 240–630 V armature drive systems using the G9 PCCA arrangement
Description
DS200PCCAG9ACB is a General Electric Power Connect Card Assembly for GE Mark V and legacy drive-control hardware.

The G9 arrangement supports 240–630 V armature service, J and M frames, DC snubbers, leg fusing and reactors, and a compatible SDCI power board.

Before installation or replacement, confirm the complete catalog number, hardware series, compatible equipment, wiring, mounting, and saved configuration.
Alternative Names
DS200PCCAG9ACB GE DS200PCCAG9ACB General Electric DS200PCCAG9ACB GE Mark V DS200PCCAG9ACB GE Speedtronic DS200PCCAG9ACB GE Drive Systems DS200PCCAG9ACB
Technical notes
DS200PCCAG9ACB requires confirmation of the 240–630 V armature class, J/M frame, SDCI board, DC snubbers, transformer, fuse, reactor, and jumper settings; an incompatible bridge arrangement can cause gate faults.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What makes General Electric DS200PCCAG9ACB a regenerative PCCA?
Its G9 configuration is documented for 240–630 V regenerative armature service and must be matched to the complete bridge, frame, power-board, and protection arrangement.
Which snubber arrangement belongs with General Electric DS200PCCAG9ACB?
The G9 card uses DC voltage snubbers; verify their location, condition, wiring, discharge state, and correspondence with the installed SCR bridge.
Why must the SDCI board be checked with General Electric DS200PCCAG9ACB?
The G9 configuration works with an SDCI power board, so group, drive input, connector routing, logic supplies, and SCR gate support must be compatible.
Which frames are appropriate for General Electric DS200PCCAG9ACB?
Use the card only after confirming the J or M frame, regenerative 240–630 V armature class, and the complete drive bill of material.
What protection hardware should be reviewed around General Electric DS200PCCAG9ACB?
Inspect the leg fuse, leg reactor, DC snubbers, bus transformer, SCR bridge, connector insulation, and documented protective clearances.
How should transformer selection be verified for General Electric DS200PCCAG9ACB?
Confirm whether the installed design uses a separate or common bus transformer and match its voltage, phasing, protection, wiring, and jumpers.
What can cause gate-pulse errors after replacing General Electric DS200PCCAG9ACB?
Check connector numbering, jumpers, SDCI interface, pulse-transformer paths, SCR wiring, snubbers, fuse continuity, and the drive's regenerative configuration.