    Apter Power supplies Honeywell FX-USI-0002 V1.0 modules for maintenance and migration projects, with revision, condition, availability, and documentation confirmed during quotation.

FX-USI-0002 V1.0

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell FX-USI-0002 V1.0 is a Universal Safety Interface module with EUCN functionality for supported Safety Manager controller configurations.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for FX-USI-0002 V1.0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for FX-USI-0002 V1.0

  • Manufacturer:
    Honeywell
  • Part Number:
    FX-USI-0002 V1.0
  • Product Family:
    Honeywell Safety Systems
  • Product Type:
    Universal Safety Interface Module
  • Stock:
    1
  • Supply Voltage:
    5 VDC ±5%
  • Typical Current Consumption:
    1.2 A
  • Operating Temperature:
    –5°C to +70°C
  • Storage Temperature:
    –40°C to +85°C
  • Relative Humidity:
    5–95% RH, non-condensing
  • Minimum Supported Release:
    Safety Manager R140.1
  • Enhanced-Function Release:
    Safety Manager R151.1 or later
  • Weight:
    0.7 kg
  • Estimated shipping dimensions:
    3.5x22.6x17.5cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Compatibility Connectivity Configuration

Features:

  • Provides the Universal Safety Interface function within supported Honeywell Safety Manager controller configurations.
  • Supports redundant Safety Manager controller configurations containing paired compatible USI modules.
  • Provides pin-to-pin and functional compatibility with FE-USI-0002, FC-USI-0002, and FC-USI-0001 on Safety Manager R140.1 or later.
Honeywell FX-USI-0002 V1.0 provides the Universal Safety Interface function within the Safety Manager controller architecture. Honeywell identifies the module as “Universal Safety Interface MMEM CC, EUCN,” distinguishing it from field-level Universal Safety I/O modules.

Honeywell FX-USI-0002 V1.0 can operate in a redundant Safety Manager controller with another compatible USI module. Honeywell states that it can function with FE-USI-0002, FC-USI-0002, or FC-USI-0001 in the redundant controller arrangement.

Honeywell FX-USI-0002 V1.0 is the designated replacement for FE-USI-0002, FC-USI-0002, and FC-USI-0001. Pin-to-pin and functional compatibility requires Safety Manager R140.1 or later and compliance with the applicable Honeywell replacement procedure.

The FX-USI-0002 V1.0 HONEYWELL Universal Safety Interface Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell FX-USI-0002 V1.0 Universal Safety Interface Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Honeywell FX-USI-0002 V1.0 Universal Safety Interface Module

General

  • Manufacturer HONEYWELL
  • Model FX-USI-0002 V1.0
  • Condition New Original ready stock
  • Product Family FE-USI-0002, FC-USI-0002, FC-USI-0001
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Successor Role: FX-USI-0002 V1.0 is Honeywell's designated successor to the withdrawn FE-USI-0002 module.
  • Pin Compatibility: FX-USI-0002 V1.0 is pin-to-pin compatible with FE-USI-0002, FC-USI-0002, and FC-USI-0001.
  • Functional Compatibility: FX-USI-0002 V1.0 can perform the predecessor module function when installed under supported software conditions.
  • Redundant Operation: FX-USI-0002 V1.0 can operate with a compatible predecessor USI module in a redundant Safety Manager controller.
  • EUCN Functionality: Honeywell identifies FX-USI-0002 V1.0 as a Universal Safety Interface MMEM CC module with EUCN functionality.
  • Protocol Scope: Honeywell's published FX-USI-0002 information does not identify HART, Modbus TCP, Modbus RTU, or EtherNet/IP as direct module interfaces.
  • External Interfaces: Engineers should verify field and supervisory protocol requirements against the applicable Safety Manager I/O and communication hardware.
  • Controller Role: FX-USI-0002 V1.0 operates within the Safety Manager controller architecture rather than as a general-purpose field protocol gateway.
  • Minimum Release: Configure FX-USI-0002 V1.0 only in Safety Manager R140.1 or later.
  • Enhanced Functions: Use Safety Manager R151.1 or later to access the enhanced FX-USI-0002 functions.
  • Module Update: When replacing FC-USI-0001, update the configured controller module type to USI-0002.
  • Application Load: Compile and load the modified application through the standard Honeywell Online Modification procedure.
Description
Honeywell FX-USI-0002 V1.0 is a Universal Safety Interface module for the Honeywell Safety Manager controller architecture. Honeywell identifies the product as a Universal Safety Interface MMEM CC module with EUCN functionality.

Honeywell FX-USI-0002 V1.0 is pin-to-pin and function compatible with FE-USI-0002, FC-USI-0002, and FC-USI-0001. It can replace these predecessor modules online and can operate with a compatible predecessor USI module in a redundant controller when the applicable Honeywell procedure is followed.

Honeywell FX-USI-0002 V1.0 requires Safety Manager R140.1 or later. Its enhanced functions require Safety Manager R151.1 or later, and replacing FC-USI-0001 requires updating the configured module type to USI-0002.

Honeywell FX-USI-0002 V1.0 operates from 5 VDC ±5% with a typical current consumption of 1.2 A. The applicable environmental ranges are -5°C to +70°C for operation, -40°C to +85°C for storage, and 5–95% relative humidity without condensation.
Alternative Names
FX-USI-0002 FX-USI-0002 V1.0 FX-USI-0002 Rev. 10 FE-USI-0002 FC-USI-0002 FC-USI-0001
Technical notes
Before installing Honeywell FX-USI-0002 V1.0, verify that the Safety Manager system runs R140.1 or later and follow the applicable Honeywell online replacement procedure. To enable the module's enhanced functions, use R151.1 or later, change the configured module type to USI-0002, and complete the standard Online Modification workflow.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What role does Honeywell FX-USI-0002 V1.0 perform in a Safety Manager system?
Honeywell FX-USI-0002 V1.0 performs the Universal Safety Interface function within the Safety Manager controller architecture. It is identified by Honeywell as an MMEM CC module with EUCN functionality, not as a general-purpose field I/O or protocol gateway.
What should a purchaser verify before ordering Honeywell FX-USI-0002 V1.0?
The purchaser should verify the physical revision, module condition, seller-reported stock, Safety Manager software release, and availability of the applicable Honeywell replacement documentation. Representative product images alone cannot confirm the supplied revision.
Can Honeywell FX-USI-0002 V1.0 replace an older USI module online?
Yes. Honeywell FX-USI-0002 V1.0 can replace FE-USI-0002, FC-USI-0002, or FC-USI-0001 online according to Honeywell's replacement guidance. The system must run Safety Manager R140.1 or later, and the applicable replacement procedure must be followed.
When can the enhanced functions of Honeywell FX-USI-0002 V1.0 be used?
The enhanced functions require Safety Manager R151.1 or later. When replacing FC-USI-0001, engineers must change the configured module type to USI-0002, compile the application, and load it through the standard Online Modification procedure.
Can Honeywell FX-USI-0002 V1.0 operate with an older USI module in a redundant controller?
Yes. Honeywell states that FX-USI-0002 V1.0 can function with FE-USI-0002, FC-USI-0002, or FC-USI-0001 in a redundant Safety Manager controller, subject to the supported software and replacement requirements.
Does Honeywell FX-USI-0002 V1.0 directly support HART, Modbus, or EtherNet/IP?
Honeywell's published FX-USI-0002 V1.0 information confirms EUCN functionality but does not document HART 7.0, Modbus TCP, Modbus RTU, or EtherNet/IP as direct module interfaces. Engineers should verify any project-specific interface requirement against the applicable Safety Manager hardware documentation.