Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com

T9090M

/ 4.9
1001 reviews | Need a Specific Revision?
T9090M is AADvance-Trusted SIS Workstation software version 2.00.x for configuring safety controllers, affected by an anomaly that resets I/O configurations to defaults.
In Stock
Ships by Saturday, October 17
Fast Shipping Available
Get a quick price for T9090M
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for T9090M

  • Manufacturer:
    ICS Triplex
  • Part Number:
    T9090M
  • Product Family:
    AADvance Controller
  • Product Type:
    Software
  • Stock:
    1
  • Affected Versions:
    2.00.00, 2.00.01, 2.00.02, 2.00.03, 2.00.04
  • Software Function:
    Configuration, programming, engineering
  • Anomaly:
    I/O Equipment configurations reset to default values
  • Trigger Actions:
    Restoring .vsc archive; opening project from source control; getting deleted controller via
  • Correction:
    Software update from Rockwell Automation PCDC
  • Unaffected Method:
    Importing .mdb or .accdb database files
  • Hardware Impact:
    None (AADvance controller hardware not affected)
  • Weight:
    0.1 kg
  • Estimated shipping dimensions:
    19x14x1.5cm
  • Tariff Code:
    8523492090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Application Diagnostics & Protection Upgrade Guide

Features:

  • T9090M is AADvance-Trusted SIS Workstation software version 2.00.x for configuring safety controllers.
  • Affected versions 2.00.00-2.00.04 may reset I/O equipment settings to default values during archive restore.
  • Workaround requires performing "Get Version" command; correction requires software update from Rockwell Automation PCDC.
The T9090M is part of the AADvance-Trusted SIS Workstation (SISW) family, a software platform used to configure, program, and maintain AADvance safety controllers certified for IEC 61508 SIL 2 and SIL 3 applications. This engineering tool supports the development of safety logic for emergency shutdown (ESD) systems, fire and gas (F&G) detection, burner management systems (BMS), and critical process control. The software provides the interface for setting up I/O modules, defining raw-engineering conversion values, establishing threshold limits, and configuring safety parameters such as Process Safety Time.

A Product Notice (Reference: 2025-03-002, Version 2.0, May 2025) identifies a specific anomaly affecting T9090M versions 2.00.x. When performing certain actions—restoring a project from an archive (.vsc) file, opening a project from source control when the project is not present in the projects folder, or getting a deleted controller from source control using "Get Version"—the software may reset I/O Equipment configurations to default values. The affected settings include raw-engineering conversion values (e.g., 4-20 mA scaling), threshold values (high/low alarm limits), the Process Safety Time "Inherit" checkbox, and Battery Alarm/Remote Fault Reset configurations.

Rockwell Automation has provided a temporary workaround for T9090M users while a permanent software fix is developed. After performing any of the triggering actions, the user must select the desired project version and perform a "Get Version" command via File > Version Control > View History. This action restores the correct I/O Equipment configuration values from version control. The workaround must be applied each time the triggering actions are performed. For users who import database files (.mdb, .accdb) instead of archive (.vsc) files, the anomaly does not occur.

The T9090M ICS TRIPLEX Software may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).

ICS TRIPLEX T9090M Software Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ICS TRIPLEX T9090M Software Specs

General

  • Manufacturer ICS TRIPLEX
  • Model T9090M
  • Condition New Original ready stock
  • Product Family T9084U,T9083D,T9082D,T9083U
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Emergency Shutdown Systems (ESD): Initiating rapid, automated shut-offs when critical process loops (pressure, temperature, flow) breach safe operating limits.
  • Fire and Gas Systems (F&G): Monitoring flame, smoke, and toxic/combustible gas detectors to trigger active mitigation and localized alarms.
  • Burner Management Systems (BMS): Ensuring safe start-up, operation, and rapid fuel isolation for industrial boilers, furnaces, and thermal oxidizers.
  • Critical Process Control (PRC): Managing environments that cannot afford a loss of control or unexpected downtime, such as offshore oil platforms, nuclear power generation, and chemical synthesis.
  • I/O Channel Diagnostics: Tracks raw engineering variables across fields and monitors for short circuits, line breakage, and out-of-bounds voltage anomalies down to the specific module channel.
  • Process Safety Time Validation: Supports safety loop configurations (such as inheriting channel parameters) to guarantee the execution speed matches the plant’s required safety windows.
  • Locked Variables Window: Features a dedicated tracking monitor for bypassed or forced values. This alerts operators to any human interventions that could unintentionally disable safety interlocks during live tuning.
  • OS Compatibility: Intended for deployment on Windows 10 Enterprise workstation environments.
  • Legacy Paths: T9090M (SISW) serves as the official modern programming environment designed to phase out the legacy AADvance Workbench (T908x series).
  • Version Upgrades: Migrating architectures across major milestones (such as from SISW 1.x to SISW 2.x) demands a corresponding Upgrade License.
  • Licensing Core: SISW v1.1 and beyond relies on standard FactoryTalk Activation mechanics, making it incompatible with older Workbench legacy serial strings.
Description
The T9090M is a software product within the AADvance-Trusted SIS Workstation (SISW) family, specifically versions 2.00.00 through 2.00.04. This engineering tool is used to configure and program AADvance safety controllers for SIL 2 and SIL 3 applications. 

The anomaly affecting T9090M causes I/O Equipment configurations to reset to default values. Specifically, when restoring a project from an archive (.vsc) file, opening a project from source control (when not present in the projects folder), or getting a deleted controller using "Get Version," the T9090M software may reset critical parameters. 

Default values that may be improperly applied by T9090M include raw-engineering conversion values (e.g., 4-20 mA default scaling) and threshold values. The Process Safety Time "Inherit" checkbox and Remote Fault Reset settings may also revert to defaults. 

A temporary workaround for T9090M users exists: after performing any triggering action, select the desired project version and perform a "Get Version" command (File > Version Control > View History). This restores the correct I/O Equipment configuration values. 
Alternative Names
T9O9OM T9084U T9083D T9082D T9083U T9193 T9191 T9087
Technical notes
The T9090M is SIS Workstation software version 2.00.x for AADvance controllers. A known anomaly (Reference: 2025-03-002) resets I/O Equipment configurations (conversion values, thresholds, Process Safety Time) to defaults when restoring .vsc archives or using source control. Workaround: Perform "Get Version" after triggering actions.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is T9090M used for?
T9090M is engineering software for configuring AADvance safety controllers. It programs SIL 2/SIL 3 applications for emergency shutdown and fire & gas systems.
What versions of T9090M are affected?
T9090M versions 2.00.00, 2.00.01, 2.00.02, 2.00.03, and 2.00.04 are affected. Version information is found in the
How do I work around the T9090M anomaly?
After triggering the issue, use T9090M to perform
Does the T9090M anomaly affect hardware?
No. The T9090M software anomaly does not affect AADvance controller hardware. Only the engineering workstation software is impacted.