  • Manufacturer:
    Invensys
  • Part Number:
    RH916FN
  • Product Family:
    Foxboro
  • Product Type:
    Type 4 P/PVC Cable
  • Stock:
    1
  • Cable type:
    Type 4 P/PVC
  • Cable function:
    FBM-to-termination-assembly cable
  • Cable length:
    20.0 m (65.6 ft)
  • Conductor size:
    26 AWG
  • Outer jacket:
    Polyurethane
  • Primary conductor insulation:
    Semi-rigid PVC
  • Legacy order number:
    P0916FN
  • Cable temperature rating:
    -20 to +80°C
  • Tariff Code:
    8544421100
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Current Identity Construction Installation Application
  • Provides a 20 m Type 4 FBM-to-TA connection
  • Uses polyurethane-jacket/PVC-insulation cable construction
  • Supersedes the legacy P0916FN order number

RH916FN is the current Foxboro order number for the 20 m Type 4 P/PVC cable.

It must be selected as part of the documented FBM, cable and termination-assembly combination rather than by length alone.

Before installation, inspect both connectors and verify endpoint identities, shielding, routing and environmental requirements.

Availability, condition, price, and shipping time for RH916FN are confirmed during quotation.

Foxboro RH916FN Type 4 P/PVC Cable Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • RH916FN is the current documented order number
  • It supersedes legacy P0916FN
  • It retains the documented 20 m Type 4 P/PVC identity
  • Uses a polyurethane outer jacket
  • Uses semi-rigid PVC primary insulation
  • Uses documented 26 AWG conductors
  • Verify both compatible endpoints
  • Protect connector keying and pins
  • Maintain shielding and cable routing
  • Current replacement cable for legacy P0916FN installations
  • Twenty-metre Type 4 FBM-to-termination-assembly connections
  • Supported remote termination-assembly wiring in Foxboro 200 Series I/O
Description
RH916FN is the current 20 m Type 4 P/PVC cable used in compatible Foxboro 200 Series FBM-to-termination-assembly wiring.

Its documented polyurethane outer jacket and semi-rigid PVC primary insulation distinguish the P/PVC construction.

Selection requires exact endpoint compatibility, correct connector orientation and the documented 20 m cable route.
Alternative Names
RH916FN RH 916 FN Foxboro RH916FN Invensys RH916FN Invensys Foxboro RH916FN Type 4 P/PVC RH916FN P0916FN
Technical notes
Foxboro RH916FN is the current 20 m Type 4 P/PVC cable and supersedes P0916FN. Confirm both endpoint part numbers, connector keying, shielding and route before installation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Does Foxboro RH916FN directly replace P0916FN?
Yes. Official Foxboro documentation states that RH916FN supersedes P0916FN, but both endpoints and the installed cable topology should still be verified.
Can Foxboro RH916FN connect any FBM to any termination assembly?
No. Type 4 cable compatibility depends on the documented FBM and termination-assembly combination and connector arrangement.
Is Foxboro RH916FN suitable when a shorter cable is required?
Do not coil, cut or substitute solely by convenience; confirm the documented allowable cable length and routing for the specific product combination.
Can Foxboro RH916FN be routed beside high-power conductors?
Follow the official separation, shielding and grounding practices; poor routing can introduce noise or violate installation requirements.
Why can Foxboro RH916FN pass continuity but still cause channel errors?
Check connector pin condition, shield continuity, endpoint compatibility, common references, cable damage and the application channel mapping.
What should be recorded before replacing Foxboro RH916FN?
Record both endpoint part numbers, connector orientation, cable route, shield termination, channel assignments and any environmental exposure.
How should Foxboro RH916FN be tested after installation?
Verify connector seating and cable integrity, then test each affected I/O channel, diagnostics and fail-safe behavior under controlled conditions.