TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05
TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05
TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05
TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05
TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05
TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, official documents, system matching, and application guidance.

TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05

/ 4.9
1001 reviews | Need a Specific Revision?
Vibro-Meter TQ902-011 configured proximity transducer for a 2 mm / 4 mm IQS900 measurement chain with 5 m integral cable.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05

  • Manufacturer:
    Vibro-Meter
  • Part Number:
    TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05
  • Product Family:
    IQS900 Proximity Signal Conditioners
  • Product Type:
    Vibro-Meter TQ902 proximity transducer for an IQS900 measuring chain
  • Stock:
    1
  • Probe family:
    TQ902 proximity transducer
  • Measuring-chain range:
    2 mm or 4 mm with matching IQS900 electronics
  • Tip diameter:
    8.2 mm
  • Mounting thread:
    M10 × 1
  • Body length:
    40 mm
  • Unthreaded length:
    2 mm
  • Integral cable:
    5 m
  • Protection:
    IP68
  • Operating temperature:
    -40 to +180 °C
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Switzerland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Sensor Build IQS900 Chain Installation & Gap Product Applications

Features:

  • Standard-mount sensor: The 8.2 mm sensing tip and 40 mm M10 × 1 body fit compact machinery measurement points.
  • Five-metre integral cable: The configured self-locking lead provides a direct route to a nearby IQS900 conditioner.
  • Industrial sensing assembly: The sensor tip and integral cable are rated IP68, with documented operation from −40 to +180 °C.
Range decision: Pair the probe with the 2 mm or 4 mm IQS900 range required by the machine movement.

Installation decision: Confirm body reach, static gap and protection of the unarmored five-metre cable before commissioning.

Signal decision: Use the conditioned dynamic output for machinery protection or spectral analysis only after the static gap is set.

Apter Power supports Vibro-Meter TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 with technical documentation, quotations and configuration review.
Vibro-Meter TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 Proximity Transducer Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Mounting style: TQ902 is the standard-mount sensor in the TQ9x2 proximity family.
  • Sensing tip: The 8.2 mm tip is designed for a 2 mm or 4 mm measurement range, depending on the IQS900 configuration.
  • Body geometry: The M10 × 1 body is 40 mm long with a 2 mm unthreaded section at the sensing end.
  • Ingress protection: The sensor tip and integral cable carry an IP68 protection rating when correctly installed.
  • Conditioner: Use an IQS900 configured for the required 2 mm or 4 mm range and voltage or current output.
  • Frequency response: The complete TQ902, EA902 and IQS900 chain is specified from DC to 20 kHz at the -3 dB point.
  • Extension option: EA902 is the compatible extension-cable family when additional electrical length is required.
  • Interchangeability: Components within the documented chain are designed to be interchangeable without pair calibration.
  • Static position: Set the cold gap from the IQS900 output so expected shaft movement remains inside the selected linear range.
  • Target material: Use the specified ferromagnetic target or assess the scale-factor change for another alloy.
  • Cable support: Restrain the 5 m integral lead against abrasion, sharp bends and movement at the probe body.
  • Connector seating: Fully engage the self-locking connector and keep its contacts clean and dry.
  • Radial vibration: Measure shaft motion relative to the bearing or casing on rotating machinery.
  • Axial position: Observe thrust movement with the probe facing an appropriate collar or shaft target.
  • Spectral analysis: Use the IQS900 dynamic output for waveform and frequency-domain assessment.
  • Protection channels: Provide a validated proximity input for machinery alarms, trips and condition monitoring.
Description
The TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 is a standard-mount eddy-current sensor for a TQ902, EA902 and IQS900 proximity measurement chain. It observes a conductive target without contact so the conditioner can reproduce both steady shaft position and dynamic shaft movement.

This TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 configuration combines the compact 40 mm threaded body with a 5 m integral cable and self-locking connection. The shorter unprotected lead is useful where the IQS900 can be installed nearby and the machine layout already provides a controlled cable route.

With the appropriate IQS900 range and output option, the TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 supports machinery-protection and condition-monitoring channels for relative vibration or axial displacement. The measurement remains a complete-chain function, so probe position, target material, cable condition and conditioner configuration must agree before the signal is used for alarms or analysis.
Alternative Names
TQ902-011 111-902-000-011 TQ902 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 TQ902-011 C40 D2 E5000 Vibro-Meter TQ902-011 Meggitt TQ902-011 TQ902 IQS900 5 m probe
Technical notes
Treat TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 as one element of a calibrated proximity chain. A plausible fault can originate from probe gap, target geometry, cable damage, connector contamination, grounding, or the IQS900 setting. Record the static gap voltage and channel scale before disturbing the installed assembly.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What must be matched with TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 before installation?
Use the documented IQS900 conditioner and extension-cable arrangement for the selected 2 mm or 4 mm measuring chain.
Why can TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 show an incorrect gap voltage?
Check probe-to-target gap, target material, cable continuity, connector cleanliness, grounding and the conditioner configuration before replacing hardware.
How should TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 cable be routed?
Keep the integral cable away from sharp bends, hot surfaces and high-energy conductors, and protect the connector from contamination.
Can TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 be shortened in the field?
No field shortening should be assumed because cable length is part of the matched electrical chain; follow the OEM configuration.
What target is suitable for TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05?
Use the ferromagnetic target and target geometry specified for the Vibro-Meter proximity system; material changes can alter scale and linearity.
How is TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05 checked during commissioning?
Verify mechanical clearance, static gap voltage, channel scale, alarm logic and shaft runout with the machine in a controlled condition.
What causes unstable readings from TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05?
Inspect mounting rigidity, connector seating, shield and ground arrangement, nearby interference, target condition and vibration outside the expected band.