Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle Status

    Discontinued

    Discontinued date: 2022-12-31

    Replacement category: Engineering Replacement

    Engineering replacement: 2198-C1004-ERS

2093-AC05-MP1

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2093-AC05-MP1 is a discontinued Kinetix 2000 230 V-class Integrated Axis Module with a 3.0 kW converter and 0.3 kW inverter section.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2093-AC05-MP1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2093-AC05-MP1

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2093-AC05-MP1
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Kinetix 2000 Integrated Axis Module
  • Stock:
    1
  • AC Input:
    170...264 V rms single-phase or three-phase
  • Input Frequency:
    47...63 Hz
  • DC-bus Output:
    325 V DC
  • Converter Output:
    3.0 kW three-phase; 2.0 kW single-phase
  • Inverter Output:
    0.3 kW
  • Continuous Current:
    1.0 A rms
  • Peak Current:
    3.0 A rms for up to 3 seconds
  • PWM Frequency:
    8 kHz
  • Internal Capacitance:
    540 µF converter; 200 µF inverter
  • Efficiency:
    95% converter; 98% inverter
  • Estimated shipping dimensions:
    9.0 × 16.75 × 17.3 cm
  • Tariff Code:
    8537101990
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Rail SERCOS Protection Application
  • Integrated converter and one inverter position in one Bulletin 2093 module
  • Supplies the shared 325 V DC bus for permitted Kinetix 2000 axis modules
  • SERCOS interface supports Logix-based coordinated motion control

2093-AC05-MP1 provides the line-side conversion function and the first servo-axis position in a compact Kinetix 2000 power-rail system.

Its integrated architecture lets the same module establish the common DC bus and control one motor-feedback channel while additional axis modules share the correctly sized rail.

Confirm the power rail, total utilization, regeneration profile, motor-feedback pair, SERCOS configuration, connector hardware, cooling, and grounding before commissioning.

Availability, condition, price, and shipping time for 2093-AC05-MP1 are confirmed during quotation.

Allen-Bradley 2093-AC05-MP1 Kinetix 2000 Integrated Axis Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • The integrated axis module occupies the converter slot and one inverter slot
  • Additional axis modules are installed to the right on the selected Bulletin 2093 power rail
  • Unused rail positions require 2093-PRF slot fillers
  • The Kinetix 2000 system connects to a compatible Logix SERCOS interface module
  • Transmit and receive fiber connections form the documented SERCOS ring
  • Node addressing and motion-axis configuration are completed in the Logix project
  • Branch-circuit protection must follow the Kinetix 2000 installation requirements
  • The internal shunt is rated 15 W continuous and 3000 W peak
  • Grounding and enclosure clearances must be completed before power is applied
  • Compact single-axis machines that require an integrated line-side converter
  • Small coordinated-motion systems using additional Bulletin 2093 axis modules
  • Logix SERCOS machine sections built around a shared Kinetix 2000 power rail
Description
2093-AC05-MP1 is an Allen-Bradley Kinetix 2000 Integrated Axis Module that combines the line-side converter and one inverter section on a Bulletin 2093 power rail.

It accepts 170...264 V rms single-phase or three-phase input at 47...63 Hz, supplies a 325 V DC bus, and provides 0.3 kW inverter output with 1.0 A rms continuous and 3.0 A rms peak current for up to 3 seconds.

Before installation or replacement, verify the power-rail catalog number, total rail utilization, motor-feedback combination, SERCOS configuration, connector kit, 2090-series cables, shunt duty, cooling, and grounding.
Alternative Names
2093-AC05-MP1 2093AC05MP1 2093 AC05 MP1 Allen-Bradley 2093-AC05-MP1 Allen Bradley 2093-AC05-MP1 AB 2093-AC05-MP1 Rockwell Automation 2093-AC05-MP1 Kinetix 2000 2093-AC05-MP1
Technical notes
Confirm the Bulletin 2093 power rail, connected-axis utilization, SERCOS configuration, motor-feedback pair, connector kit, shunt duty, cooling, and grounding before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What should be checked before replacing an Allen-Bradley 2093-AC05-MP1?
Match the complete catalog number, Bulletin 2093 power rail, connected-axis utilization, SERCOS node configuration, motor-feedback pair, connector kit, cabling, shunt duty, and enclosure design before replacement.
Can Allen-Bradley 2093-AC05-MP1 supply additional Kinetix 2000 axis modules?
Yes. As the integrated axis module, it supplies the common DC bus for permitted axis modules on the same power rail, but the full rail load and regenerative profile must remain within Rockwell Automation sizing limits.
Which position should Allen-Bradley 2093-AC05-MP1 occupy on the power rail?
Install the integrated axis module at the left end of the Bulletin 2093 power rail, followed by axis modules in the order specified by the Kinetix 2000 installation instructions.
What network configuration must be preserved when replacing Allen-Bradley 2093-AC05-MP1?
Preserve the Logix SERCOS ring design, node addresses, firmware compatibility, and motion-axis configuration. Verify every setting against the installed controller project before commissioning.
Does Allen-Bradley 2093-AC05-MP1 include the motor and feedback cables?
No. The drive module and the required 2090-series motor-power, feedback, and interface cables are separate selections. Match them to the documented motor-feedback combination.
What is the engineering replacement for Allen-Bradley 2093-AC05-MP1?
Rockwell Automation lists 2198-C1004-ERS as the engineering replacement. It is not a drop-in swap; review the supply, controller, feedback, cabling, dimensions, and safety architecture.
What information should be provided when requesting Allen-Bradley 2093-AC05-MP1?
Provide the complete catalog number, quantity, required condition, nameplate photos, installed hardware Series, controller and firmware information, motor catalog number, and destination.