Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active
    Apter Power provides quotations, procurement support, official technical documentation, and system-matching guidance for 2198-C4075-ERS.

2198-C4075-ERS

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2198-C4075-ERS is a Frame 3 Kinetix 5300 400 V-class Servo Drive rated 14.70 kW, 27.5 A rms continuous, and 73.5 A rms peak.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2198-C4075-ERS
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2198-C4075-ERS

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2198-C4075-ERS
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Servo Drive
  • Stock:
    1
  • Input Voltage:
    342...528 V rms three-phase
  • Frame Size:
    Frame 3
  • Continuous Output Power:
    14.70 kW at 480 V three-phase
  • Continuous Output Current:
    27.5 A rms
  • Peak Output Current:
    73.5 A rms
  • Network:
    Integrated Motion over EtherNet/IP
  • Safety Option:
    Hardwired Safe Torque Off (STO)
  • Weight:
    3.81 kg
  • Estimated shipping dimensions:
    8.52 × 25.0 × 29.4 cm
  • Tariff Code:
    8503009090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Power Control Power Safety I/O Application

Features:

  • Frame 3 Kinetix 5300 400 V-class Servo Drive
  • 14.70 kW output at the documented 480 V three-phase condition
  • 27.5 A rms continuous and 73.5 A rms peak output current
Allen-Bradley 2198-C4075-ERS accepts 342...528 V rms three-phase input and provides Integrated Motion over EtherNet/IP with Hardwired Safe Torque Off (STO).

Official design data publishes a TLP-B200-750 motor torque-speed curve for this Frame 3 drive.

Confirm the motor torque-speed profile, feedback and brake interfaces, Frame 3 wiring, controller configuration, cable set, branch protection, axis duty, regeneration, enclosure cooling, grounding, and Safe Torque Off wiring before selection or migration.

Availability, condition, price, and shipping time for 2198-C4075-ERS are confirmed during quotation.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Main AC input current is documented as 21.29 A rms
  • Maximum inrush current is documented as 46.4 A from zero to peak
  • Peak AC input current is documented as 49.72 A rms
  • Control-power input range is 21.6...26.4 V DC
  • Nominal control-power input is 24 V DC
  • Control-power input current is 1.7 A DC with a non-brake motor
  • 2198-Cxxxx-ERS drives ship with the Hardwired Safe Torque Off (STO) function enabled
  • The Safe Torque Off connector provides paired S1, SC, and S2 safety-input terminals
  • The Safe Torque Off inputs must be connected to the safety circuit or correctly bypass-wired before motion can be enabled
  • High-output rotary servo axes using the documented TLP-B200-750 motor combination
  • Ultra3000 migration projects where Rockwell Automation identifies 2098-DSD-HV220-SE as the predecessor
  • Studio 5000 axis configurations with both Module and Power Structure set to 2198-C4075-ERS
Description
2198-C4075-ERS is an Allen-Bradley Kinetix 5300 Frame 3 Servo Drive for high-output 400 V-class single-axis motion applications.

It accepts 342...528 V rms three-phase input and delivers 14.70 kW at 480 V three-phase, with 27.5 A rms continuous output current and 73.5 A rms peak output current.

Integrated Motion over EtherNet/IP and Hardwired Safe Torque Off (STO) support Logix-based machine designs. Confirm the motor torque-speed profile, feedback and brake interfaces, Frame 3 conductor sizing, branch protection, cable set, axis duty, regeneration, enclosure cooling, controller configuration, grounding, and Safe Torque Off wiring before installation or migration.
Alternative Names
2198-C4075-ERS 2198-C4075ERS 2198 C4075 ERS 2198C4075ERS Allen-Bradley 2198-C4075-ERS Allen Bradley 2198-C4075-ERS AB 2198-C4075-ERS Rockwell Automation 2198-C4075-ERS Kinetix 5300 2198-C4075-ERS
Technical notes
Allen-Bradley 2198-C4075-ERS is a Frame 3 Kinetix 5300 400 V-class Servo Drive for 342...528 V rms three-phase input. It is rated 14.70 kW at 480 V three-phase, with 27.5 A rms continuous output current and 73.5 A rms peak output current. Verify the motor torque-speed profile, three-phase supply, Frame 3 power conductors, branch protection, regeneration, enclosure cooling, cable set, grounding, and Hardwired Safe Torque Off (STO) circuit before installation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What output ratings distinguish Allen-Bradley 2198-C4075-ERS?
Allen-Bradley 2198-C4075-ERS accepts 342...528 V rms three-phase input and provides 14.70 kW at 480 V three-phase. Its documented output ratings are 27.5 A rms continuous and 73.5 A rms peak for up to 1.0 second, in a Frame 3 enclosure.
Which Kinetix TLP motor curve is published for Allen-Bradley 2198-C4075-ERS?
Rockwell Automation publication KNX-RM012 includes a torque-speed curve for Allen-Bradley 2198-C4075-ERS with the TLP-B200-750 motor. Verify the exact winding, continuous and intermittent operating regions, 380/480 V supply condition, feedback, brake, cable, load inertia, and duty cycle with the current design guide and Motion Analyzer.
Can Allen-Bradley 2198-C4075-ERS replace a 2098-DSD-HV220-SE Ultra3000 drive?
Rockwell Automation identifies Allen-Bradley 2198-C4075-ERS as the functional replacement for 2098-DSD-HV220-SE. This does not make it a drop-in replacement. Use publication 2198-RM006 to compare physical mounting, supply and branch protection, motor and feedback compatibility, power and brake cables, 24 V control power, controller architecture, configuration, and Hardwired Safe Torque Off (STO) wiring.
What DC-bus capacitance and energy-absorption values are specified for Allen-Bradley 2198-C4075-ERS?
Rockwell Automation specifies 1230 microfarads of DC-bus capacitance and 60.60 J of capacitive energy absorption for Allen-Bradley 2198-C4075-ERS. Determine regeneration requirements from the actual motor and load inertia, maximum speed, deceleration time, repeated duty cycle, vertical load behavior, and enclosure thermal conditions.
Which branch-protection references are documented for Allen-Bradley 2198-C4075-ERS?
Rockwell Automation lists the LPJ-35SP Bussmann fuse for UL applications. For IEC non-UL applications, the documented references include a 32 A maximum DIN gG fuse, 1489-M3C400 miniature circuit breaker, and 140U-D6D3-C30 or 140UT-D7D3-C30 molded-case circuit breaker. Apply the current installation instructions and applicable electrical code.
Which Rockwell Automation publications specify Allen-Bradley 2198-C4075-ERS?
Use KNX-TD003 for drive ratings, input-power data, energy absorption, weight, dimensions, and accessories; 2198-IN021 for mounting, wiring, Hardwired Safe Torque Off (STO) connections, and circuit protection; 2198-UM005 for configuration, startup, diagnostics, and firmware; KNX-RM012 for motor combinations; and 2198-RM006 for Ultra3000 migration considerations.
What information should be included in a quotation request for Allen-Bradley 2198-C4075-ERS?
Provide the complete catalog number, quantity, destination, required condition, 480 V three-phase supply, motor catalog number, controller and Studio 5000 version, axis duty, regeneration profile, enclosure cooling, safety-circuit requirements, and required power, feedback, brake, or Ethernet cables. Apter Power will confirm availability, condition, price, and shipping time during quotation.