Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotation, widescreen-project review, official documentation, and coordinated procurement.

2711P-T12W22D8S

/ 4.9
1001 reviews | Need a Specific Revision?
Widescreen 12.1-inch PanelView Plus 7 Standard HMI with dual Ethernet ports for large DLR machine interfaces.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2711P-T12W22D8S
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2711P-T12W22D8S

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2711P-T12W22D8S
  • Product Family:
    Panelview Plus
  • Product Type:
    PanelView Plus 7 Standard Graphic Terminal
  • Stock:
    1
  • Display Size:
    12.1 in. widescreen
  • Operator Input:
    Resistive touch
  • Display Type:
    Color TFT LCD
  • Resolution:
    1280 × 800 WXGA
  • Aspect Ratio:
    16:10
  • Input Voltage:
    24 V DC
  • Communication:
    Two 10/100 Ethernet ports with DLR
  • Operating System:
    Windows CE 6
  • Weight:
    1.95 kg
  • Estimated shipping dimensions:
    24.6 × 34.0 × 5.65 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Wide DLR Indoor Product Applications

Features:

  • WXGA workspace: 12.1-inch 1280 × 800 widescreen touch display
  • Resilient topology: embedded switch supports DLR and linear networks
  • Large-panel role: broad operator view within Standard ME application limits

The 12W code identifies a widescreen canvas whose proportions differ from both 9W and the 4:3 terminals.

Its dual-port architecture suits a large local station that must remain part of a documented ring or in-line network.

Application conversion, panel fit, indoor rating, Series, and firmware are independent acceptance gates.

For 2711P-T12W22D8S, Apter Power can coordinate documentation review, quotation, and sourcing support.

Verified resources for 2711P-T12W22D8S:

Important Notice: Confirm the required firmware, application files, cables, accessories, and documentation in the quotation before ordering.
  • Native canvas: build the ME project for the 1280 × 800 target resolution.
  • Object placement: use the wide workspace without stretching 4:3 graphics or text.
  • Alarm visibility: confirm banners, lists, and acknowledgement controls remain readable.
  • Operator signoff: test navigation and touch reach across the full 12.1-inch surface.
  • Two-port role: use the embedded switch for one documented ring or linear path.
  • Ring acceptance: verify controller communication through a deliberate single-link break.
  • Switch records: retain terminal IP, device name, controller shortcut, and neighboring nodes.
  • Removal plan: provide a bypass or outage method before disconnecting an in-line HMI.
  • Enclosure scope: apply the marked Type 12, 13, and 4X indoor conditions only.
  • Panel seal: use the correct cutout, gasket, mounting levers, and flat mounting surface.
  • Environment: keep operation within 0...55 °C and 5...95% noncondensing humidity.
  • Outdoor gate: follow the separate official precautions rather than extending the indoor rating by assumption.
  • Large widescreen machine HMI: present detailed process graphics and alarms from a local touch station.
  • DLR operator node: add the large display to a supported resilient EtherNet/IP machine network.
  • Logix visualization: monitor and control one supported ControlLogix 5570 or CompactLogix 5370 controller.
Description

Wide-format operator graphics are the central value of 2711P-T12W22D8S, whose 12.1-inch 1280 × 800 touch display provides the largest Standard widescreen workspace in this batch.


Two embedded-switch ports allow 2711P-T12W22D8S to serve supported DLR, linear, or star EtherNet/IP topology while a FactoryTalk View ME application exchanges data with one supported Logix controller.


Panel structure, indoor enclosure conditions, application layout, network role, hardware Series, and firmware must be reviewed together before 2711P-T12W22D8S replaces a smaller or 4:3 operator terminal.

Revisions

Revision Part #

Also known as

2711P-T12W22D8S Series C
2711P-T12W22D8S/C, Series C
2711P-T12W22D8S Series D
2711P-T12W22D8S/D, Series D
Alternative Names
Allen-Bradley 2711P-T12W22D8S AB 2711P-T12W22D8S 2711P T12W22D8S 2711PT12W22D8S 2711P-T12W22D8S widescreen DLR HMI PanelView Plus 7 12.1-inch terminal
Technical notes
Do not download a 4:3 HMI project unchanged into 2711P-T12W22D8S. Its 1280 × 800 widescreen canvas changes object spacing, navigation, alarm visibility, and touch-target placement; rebuild the FactoryTalk View ME screens for the target resolution and complete an operator walkthrough before using the larger display in production.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why should a 4:3 ME project not be loaded unchanged into 2711P-T12W22D8S?
The terminal uses a 1280 × 800 widescreen canvas, so stretched objects can impair navigation, alarm visibility, and touch accuracy. Rebuild screens for the target resolution and complete an operator walkthrough before release.
How should DLR be validated when 2711P-T12W22D8S replaces a single-port HMI?
Document the intended two-port ring position, connect both neighboring nodes, restore the controller shortcut, and break one link under controlled conditions. Accept the change only if communication remains stable.
When is the indoor Type 4X rating of 2711P-T12W22D8S not enough?
It is not an automatic outdoor approval. Verify the marked enclosure, gasket, cutout, mounting, temperature, humidity, sun, and environmental precautions; stop the installation when those conditions exceed the official scope.
Why can an application transfer run out of space on 2711P-T12W22D8S?
The Standard terminal provides approximately 80 MB of application storage. Remove unneeded files or use supported external storage, but first preserve a complete backup and confirm the project still fits the runtime limit.
How should remote ViewPoint expectations be set for 2711P-T12W22D8S?
Plan one licensed browser client and define view or control rights before testing the large-screen application remotely. Choose another supported architecture if operations need several simultaneous remote users.
What should be sent with a 2711P-T12W22D8S sourcing request?
Provide the exact 12W22 code, Series, firmware, application backup, DLR position, panel cutout, indoor enclosure need, label photos, quantity, destination, and required date.