Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power can provide IC695ECM850 pricing, quotation assistance, and access to the applicable official General Electric technical documentation.

IC695ECM850

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC695ECM850 is a PACSystems RX3i IEC 61850 Communication Module for connecting an RX3i controller as an IEC 61850 Client.
In Stock
Ships by Saturday, October 17
Fast Shipping Available
Get a quick price for IC695ECM850
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC695ECM850

  • Manufacturer:
    General Electric
  • Part Number:
    IC695ECM850
  • Product Family:
    GE PACSystems RX3i
  • Product Type:
    PACSystems RX3i IEC 61850 Communication Module
  • Stock:
    1
  • Function:
    IEC 61850 Client
  • Network Devices:
    IEC 61850 Server IEDs
  • Configuration Software:
    PAC Machine Edition 8.00 SIM 7 or later
  • CPU Support:
    CPU315/320, CPE305/310/330, CRU320 with supported firmware
  • Primary Firmware:
    1.01
  • Engineering File:
    IEC 61850 configuration file
  • Module Setup:
    PAC Machine Edition hardware configuration
  • Mounting:
    RX3i Universal Backplane
  • Ethernet Role:
    Client communications to IEC 61850 servers
  • Tariff Code:
    8537101190
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals IEC 61850 CPU Support Diagnostics Commissioning

Features:

  • Enables a PACSystems RX3i controller to act as an IEC 61850 Client.
  • The module communicates with IEC 61850 Server intelligent electronic devices using the substation automation protocol.
  • Compatibility depends on the exact supported CPU and firmware combination for the exact supported hardware combination.
The module communicates with IEC 61850 Server intelligent electronic devices using the substation automation protocol.

Compatibility depends on the exact supported CPU and firmware combination for the exact supported hardware combination.

IC695ECM850 combines an RX3i hardware configuration, IEC 61850 engineering file, and Ethernet settings for client communication with server IEDs.

General Electric IC695ECM850 PACSystems RX3i IEC 61850 Communication Module is available for Apter Power quotation and official-documentation support.
General Electric IC695ECM850 PACSystems RX3i IEC 61850 Communication Module Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

IC695ECM850 Client Services

  • IED sessions: The client can maintain connections with multiple compatible IEC 61850 server IEDs.
  • Data access: Configured objects may be browsed, read, and written through their logical-device and logical-node paths.
  • Controls: Supported IEC 61850 control models are available when the target IED permits the selected operation.
  • Reports: Buffered and unbuffered report-by-exception services deliver configured server events to the controller.

IC695ECM850 Controller Prerequisites

  • CPU pairing: Use only a supported RX3i CPU and firmware combination for IC695ECM850.
  • Engineering tool: PAC Machine Edition 8.00 SIM 7 or later is required for IC695ECM850 configuration.
  • Hardware project: The slot, module revision, and CPU firmware must agree with the downloaded RX3i configuration.
  • Upgrade review: Recheck the compatibility table whenever either CPU or ECM850 firmware is changed.

IC695ECM850 Diagnostic Layers

  • Physical link: Confirm the selected copper or fiber interface reports link at a rate supported by the network equipment.
  • Client session: Separate an Ethernet link fault from an IEC 61850 association or authentication failure.
  • Data model: A connected IED can still return invalid paths when logical devices, nodes, data sets, or report controls differ from the project.
  • Control response: Use the server result and configured control model to investigate rejected operate commands.

IC695ECM850 Project Commissioning

  • Source files: Start from the current IED capability and configuration files rather than recreating object names manually.
  • Object mapping: Bind the required server data objects and reports to the intended RX3i application variables.
  • Network validation: Test each configured IED association before enabling controls or report-dependent logic.
  • Controlled test: Exercise reads, writes, reports, and permitted commands while recording the exact CPU and ECM850 firmware levels.
Description
IC695ECM850 enables a PACSystems RX3i controller to act as an IEC 61850 Client.

The module communicates with IEC 61850 Server intelligent electronic devices by using the substation automation protocol.

Compatibility depends on the exact supported RX3i CPU, CPU firmware, and IC695ECM850 hardware combination.

Before enabling the module, validate the RX3i CPU pairing, IEC 61850 configuration file, Ethernet network settings, and supported firmware combination.
Revisions

Revision Part #

Also known as

IC695ECM850DB
IC695ECM850-DB, Series DB, Rev DB
IC695ECM850CB
IC695ECM850-CB, Series CB, Rev CB
IC695ECM850CA
IC695ECM850-CA, Series CA, Rev CA
IC695ECM850BA
IC695ECM850-BA, Series BA, Rev BA
IC695ECM850AA
IC695ECM850-AA, Series AA, Rev AA
Alternative Names
IC695 ECM850 IC695-ECM850 IC695ECM-850 GE IC695ECM850 GE Fanuc IC695ECM850 General Electric IC695ECM850 PACSystems RX3i IC695ECM850 IEC 61850 Module IC695ECM850
Technical notes
IC695ECM850 commissioning depends on the matching IEC 61850 engineering file, supported CPU firmware, network addressing, and exact module catalog revision.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why does IC695ECM850 show an Ethernet link but no IEC 61850 data?
For IC695ECM850, verify the target IED address, logical device and node references, report-control settings, and that the downloaded IEC 61850 configuration matches the server.
Can IC695ECM850 operate as an IEC 61850 Server?
For IC695ECM850, no. It provides IEC 61850 Client functions for reading, writing, controls, browsing, and report handling with compatible server IEDs.
Why is an IC695ECM850 configuration rejected after a CPU change?
For IC695ECM850, check the exact RX3i CPU model and firmware combination against the module IPI, then rebuild and download the supported hardware configuration.
Can copper and fiber IED connections be used in the same IC695ECM850 network?
For IC695ECM850, yes, when the selected copper, multimode, and single-mode interfaces and external network equipment support the required Ethernet rates and topology.
Why do buffered reports stop after IC695ECM850 is replaced?
For IC695ECM850, restore the correct client identity, data-set and report-control references, and confirm the server IED has enabled the replacement client connection.
What should be backed up before replacing IC695ECM850?
For IC695ECM850, keep the IEC 61850 project files, IED names and addresses, network settings, CPU compatibility details, slot assignment, and module firmware record.
How should an IC695ECM850 control-command failure be investigated?
For IC695ECM850, check the configured control model, select-before-operate requirement, origin and test flags, server permissions, and the returned IEC 61850 diagnostic.