    Apter Power supplies IC695CPE302 pricing, official product files, configuration review, sourcing support, and RX3i system-matching guidance.

IC695CPE302

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC695CPE302 is a backplane-mounted PACSystems RX3i controller with 2 MB user memory and embedded industrial communications.
In Stock
Ships by Saturday, October 17
Fast Shipping Available
Get a quick price for IC695CPE302
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC695CPE302

  • Manufacturer:
    General Electric
  • Part Number:
    IC695CPE302
  • Product Family:
    GE PACSystems RX3i
  • Product Type:
    PACSystems RX3i CPE302 Controller
  • Stock:
    1
  • Form Factor:
    Backplane
  • User Memory:
    2 MB
  • Non-volatile Flash:
    2 MB
  • Discrete I/O:
    16k bits
  • Analog I/O:
    32k words
  • Ethernet:
    Two Gigabit Ethernet ports
  • USB:
    1 x USB-A 2.0
  • Serial Protocols:
    ASCII Serial; Modbus RTU
  • Operating Temperature:
    0 to 60 °C
  • Programming:
    Ladder Diagram; Structured Text; Function Block Diagram; C
  • Tariff Code:
    8537101190
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Communication Compatibility Configuration Applications

Features:

  • 2 MB user memory with 2 MB non-volatile flash
  • Dual Gigabit Ethernet ports and industrial protocol support
  • Energy Pack retention and USB removable-storage operation
IC695CPE302 is the 2 MB member of the PACSystems RX3i CPE302/305/310 controller platform.

The CPU executes real-time machine and process control while communicating with I/O over the RX3i backplane and with supervisory systems through Ethernet or serial links.

Hardware platform, RX3i backplane revision, PAC Machine Edition version, Energy Pack status, and the intended PROFINET architecture must be checked together.

The General Electric IC695CPE302 PACSystems RX3i CPE302 Controller is available for quotation, official documentation, and configuration support from Apter Power.
General Electric IC695CPE302 PACSystems RX3i CPE302 Controller Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Embedded controller communications

  • Ethernet interface: Two Gigabit ports provide the controller network connection.
  • OPC UA: Encrypted OPC UA connections support secure data access within the approved firmware environment.
  • Client and server capacity: The controller supports documented SRTP and Modbus TCP server and client-channel counts.
  • Serial channel: ASCII and Modbus RTU communication are available through the serial interface.

Platform and rack requirements

  • Backplane hardware: Use only RX3i backplane revisions listed for the installed controller platform.
  • PME version: The required PAC Machine Edition release depends on hardware generation, firmware, and configured feature.
  • Remote I/O: PROFINET controller and scanner firmware must satisfy the published compatibility matrix.
  • Legacy modules: Most Series 90-30 modules and expansion racks are supported subject to the RX3i system manual.

Application and retention setup

  • Program organization: Up to 512 program blocks are supported, with a maximum block size of 128 KB.
  • Reference tables: The controller provides discrete and analog reference-table resources for the application.
  • Energy Pack: Retention depends on a connected and charged IC695ACC400 at power-down and power-up.
  • USB transfer: Approved USB 2.0 removable devices can transfer controller applications.

Supported real-time control projects

  • Machine control: IC695CPE302 can execute deterministic logic for industrial machines through the RX3i backplane and supported I/O.
  • Process control: The controller supports real-time sequencing and coordination of process equipment.
  • Material handling: RX3i communication and I/O services support conveyors and other coordinated material-handling systems.
  • Operator and supervisory links: Ethernet and serial ports connect supported programming, HMI, and SCADA systems.
Description
IC695CPE302 is a modular PACSystems RX3i controller designed for real-time control of machines, processes, and material-handling systems. Its backplane form factor connects the CPU to RX3i I/O and intelligent modules while 2 MB of user memory supports application logic and data.

Embedded Ethernet on IC695CPE302 provides high-speed controller, HMI/SCADA, and remote-I/O communication. The controller supports SRTP, Modbus TCP, OPC UA, Ethernet Global Data, PROFINET, HART pass-through, serial ASCII, and Modbus RTU functions within the approved firmware and configuration environment.

IC695CPE302 preserves user memory through the supported Energy Pack during loss of system power and can transfer applications with USB removable storage. Backplane revision, PAC Machine Edition level, PROFINET devices, Energy Pack condition, and application memory use should be reviewed before installation or migration.
Revisions

Revision Part #

Also known as

IC695CPE302-BHAE
IC695CPE302-BHAE, Series BHAE, Rev BHAE
IC695CPE302-BGAE
IC695CPE302-BGAE, Series BGAE, Rev BGAE
IC695CPE302-BGAD
IC695CPE302-BGAD, Series BGAD, Rev BGAD
IC695CPE302-BDAD
IC695CPE302-BDAD, Series BDAD, Rev BDAD
IC695CPE302-BCAD
IC695CPE302-BCAD, Series BCAD, Rev BCAD
IC695CPE302-BCAB
IC695CPE302-BCAB, Series BCAB, Rev BCAB
IC695CPE302-BBAB
IC695CPE302-BBAB, Series BBAB, Rev BBAB
IC695CPE302-BAAA
IC695CPE302-BAAA, Series BAAA, Rev BAAA
Alternative Names
IC695 CPE 302 IC695-CPE-302 GE IC695CPE302 General Electric IC695CPE302 PACSystems IC695CPE302 IC695CPE3O2 1C695CPE302 IC 695 CPE 302
Technical notes
IC695CPE302 provides compact RX3i control with 2 MB memory, embedded Gigabit Ethernet, OPC UA security functions, and Energy Pack retention.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should application memory be assessed before moving a project to IC695CPE302?
IC695CPE302 provides 2 MB of user memory, so compare the compiled application, retained variables, communication data, and planned growth with the available controller resources.
How should Ethernet services be selected for a mixed network using IC695CPE302?
IC695CPE302 supports SRTP, Modbus TCP, OPC UA, EGD, PROFINET, DNP3, IEC 61850, IEC 104, and HART pass-through; enable only the services required by the validated design.
How does IC695CPE302 preserve user data if external power is lost?
IC695CPE302 uses the supported IC695ACC400 Energy Pack to write user memory to non-volatile storage, so verify Energy Pack status and retention operation during commissioning.
What must be checked before fitting IC695CPE302 to an existing RX3i rack?
Before installing IC695CPE302, verify the RX3i backplane revision, supported power arrangement, adjacent modules, Energy Pack connection, and compatibility of the existing system hardware.
Which software and firmware checks are required before downloading to IC695CPE302?
For IC695CPE302, identify the hardware platform and firmware level, then use a compatible PAC Machine Edition version and only the approved firmware package.
How can IC695CPE302 connect remote I/O without disrupting the network design?
IC695CPE302 can serve supported remote I/O through PROFINET configurations; verify the PNC001 design, device names, IP addressing, update requirements, and controller resource limits.
What commissioning checks are needed after replacing IC695CPE302?
After replacing IC695CPE302, verify mode control, I/O scans, Energy Pack health, Ethernet clients, PROFINET devices, retained data, network settings, and the restored application.