Foxboro P0926GW is the single-port FBM232 integrator that connects supported Ethernet field devices to the Foxboro DCS Module Fieldbus.
In Stock
Ships by Saturday, October 17
Fast Shipping Available
Get a quick price for P0926GW
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for P0926GW

  • Manufacturer:
    Invensys
  • Part Number:
    P0926GW
  • Product Family:
    Foxboro
  • Product Type:
    FBM232 Field Device System Integrator Module
  • Stock:
    1
  • Ethernet interface:
    Single 10/100 Mbps copper RJ-45
  • Network protocols:
    TCP/IP or UDP/IP as driver-defined
  • Maximum field devices:
    Up to 64, driver and performance dependent
  • Maximum DCI connections:
    Up to 2,000, driver dependent
  • Module Fieldbus:
    Redundant 2 Mbps
  • Power consumption:
    7 W maximum
  • Ethernet cable length:
    1 to 100 m
  • Mounting:
    Standard 200 Series modular baseplate
  • Dimensions:
    4.5 × 10.2 × 10.4 cm
  • Operating temperature:
    Rev A to J: -20 to +70°C; Rev K and later: 0 to +70°C
  • Storage temperature:
    -40 to +70°C
  • Relative humidity:
    5 to 95%, non-condensing
  • Weight:
    0.284 kg
  • Tariff Code:
    8517629990
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Device Integration Ethernet Design Configuration Recovery Application
  • Confirm P0926GW is the single-Ethernet FBM232 rather than an analog I/O module
  • Verify that the required device driver supports the target Ethernet device and data map
  • Size the design by device count, DCI count, scan performance and network architecture

Foxboro P0926GW is the exact part number for the FBM232 single-port Field Device System Integrator module.

It links supported 10/100 Mbps Ethernet devices to a Foxboro control station through the redundant 2 Mbps Module Fieldbus.

Before selection, identify the downloadable driver, device count, DCI mapping, polling requirements, IP scheme, switch topology and controller compatibility.

Availability, condition, price, and shipping time for P0926GW are confirmed during quotation.

Foxboro P0926GW Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • A downloadable driver handles the supported device protocol
  • Up to 64 devices can be addressed when the application permits
  • Device data is mapped into DCI blocks for control-system use
  • The field port supports 10 or 100 Mbps copper Ethernet
  • Multiple devices require an appropriate hub or switch
  • IP addressing, polling and switch behavior must match the driver design
  • Preserve the XML port and device configuration
  • Archive the driver package and DCI map
  • Validate update timing and reconnect behavior after commissioning
  • Ethernet field-device integration into Foxboro DCS
  • Protocol conversion using a supported FBM232 driver
  • Data exchange between packaged equipment and DCI control blocks
Description
Foxboro P0926GW exchanges process data with supported Ethernet field devices through a driver configured for the target protocol.

The module converts device-specific communication into Foxboro DCS Distributed Control Interface data while retaining Module Fieldbus communication with an associated controller.

It is used when Ethernet-connected analyzers, PLCs or packaged systems must be integrated into the DCS without assigning their protocol handling to a general analog module.
Alternative Names
P0926GW P0926 GW Foxboro P0926GW Invensys Foxboro P0926GW FBM232 P0926GW Foxboro Evo P0926GW Invensys P0926GW
Technical notes
P0926GW is the exact FBM232 single-Ethernet module part number. Operating temperature is -20 to +70°C for Rev A–J and 0 to +70°C for Rev K and later; verify the nameplate revision and driver compatibility before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should the correct downloadable driver be selected for Foxboro FBM232 P0926GW?
Identify the field device’s protocol, firmware revision, supported data objects and required DCI mapping, then confirm that a compatible FBM232 driver package is available before ordering or configuring Foxboro FBM232 P0926GW.
Can Foxboro FBM232 P0926GW be used where redundant field-device Ethernet is required?
No. Foxboro FBM232 P0926GW provides a single field-device Ethernet connection. Applications requiring redundant Ethernet paths should be engineered with the appropriate redundant FDSI architecture rather than treating P0926GW as a redundant interface.
Does the RJ-45 port on Foxboro FBM232 P0926GW connect directly to the Foxboro control network?
No. The RJ-45 port connects Foxboro FBM232 P0926GW to the external field-device Ethernet network. Communication with the associated Foxboro control processor occurs through the Module Fieldbus and baseplate.
Why can Foxboro FBM232 P0926GW respond to a ping but provide no process data?
A successful ping confirms only basic IP communication. Check the installed driver, device definition, protocol port, DCI mapping, device addresses, byte order, polling state and any access restrictions configured in the field device.
What must be backed up before replacing Foxboro FBM232 P0926GW?
Export the XML port and device configuration, record the driver package and revision, IP settings, DCI assignments, controller database references and current communication diagnostics before removing Foxboro FBM232 P0926GW.
When is a null-hub adapter needed with Foxboro FBM232 P0926GW?
Confirm whether Foxboro FBM232 P0926GW connects through an Ethernet hub or switch or directly to the field device. A direct topology may require the documented P0971PK null-hub adapter; verify the device interface and cable arrangement before connection.
What should be tested after replacing Foxboro FBM232 P0926GW?
Verify Module Fieldbus health, Ethernet link operation, every configured field-device connection, DCI data quality and update timing, alarm behavior, communication recovery after interruption and the process logic that consumes the exchanged data.