Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides PLX32-EIP-MBTCP-UA quotations, official documents, sourcing, and OPC UA integration guidance.

PLX32-EIP-MBTCP-UA

/ 4.9
1001 reviews | Need a Specific Revision?
ProSoft PLX32-EIP-MBTCP-UA is a multi-protocol gateway linking EtherNet/IP and Modbus TCP/IP data with OPC UA clients.
In Stock
Ships by Saturday, October 17
Fast Shipping Available
Get a quick price for PLX32-EIP-MBTCP-UA
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PLX32-EIP-MBTCP-UA

  • Manufacturer:
    ProSoft
  • Part Number:
    PLX32-EIP-MBTCP-UA
  • Product Family:
    ProSoft
  • Product Type:
    EtherNet/IP to Modbus TCP/IP to OPC UA Server Gateway
  • Stock:
    1
  • Number of Class 3 Server Connections:
    5
  • Supported Message Types:
    PCCC and CIP
  • Class 3 Client Connections:
    Connected: 2; Unconnected: 1
  • Number of Class 1 I/O Connections:
    8
  • I/O connection sizes:
    248/248
  • Max RPI time:
    5 ms per connection
  • EtherNet/IP Command Capacity:
    Support for 100 commands (Class 3 MSG) per Client
  • Command Sets:
    PLC-2/PLC-3/PLC5/SLC500
  • Supported Function Codes:
    1, 2, 3, 4, 5, 6, 15, 16, 22 and 23 (Slave only)
  • Supported Clients:
    10
  • Supported Servers:
    MBAP: 5; Encapsulated: 5
  • Modbus Client Commands:
    Up to 160 fully configurable Client commands
  • Status Data:
    Error codes reported individually for each command
  • Client Connections:
    10 simultaneous connections supported
  • Power Supply:
    24 VDC nominal; 10 to 36 VDC allowed; Positive, Negative, GND Terminals
  • Current Load:
    24 VDC nominal @ 300 mA; 10 to 36 VDC @ 610 mA maximum
  • Operating Temperature:
    -25°C to 70°C (-13°F to 158°F)
  • Storage Temperature:
    -40°C to 80°C (-40°F to 176°F)
  • Relative Humidity:
    5% to 95% RH with no condensation
  • Weight:
    1.2 kg
  • Estimated shipping dimensions:
    5.38 x 1.99 x 4.38 in / 13.67 x 5.05 x 11.13 cm
  • Tariff Code:
    8517.62
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Protocols OPC UA Networking

Features:

  • EtherNet/IP, Modbus TCP/IP, and OPC UA communications
  • Two Ethernet ports for separate protocol subnets
  • Integrated OPC UA Server with configurable security
The ProSoft PLX32-EIP-MBTCP-UA combines EtherNet/IP, Modbus TCP/IP, and OPC UA Server connectivity in one gateway for transferring industrial controller data to automation and information-system clients.

Independent protocol connections feed a common internal database, allowing mapped EtherNet/IP and Modbus values to be exposed through the OPC UA namespace. Multiple client sessions and security settings are managed in the gateway configuration.

Define tag mapping, Modbus register ranges, EtherNet/IP connection parameters, OPC UA endpoints, certificates, user security, IP addressing, and time synchronization before commissioning.
The ProSoft PLX32-EIP-MBTCP-UA EtherNet/IP to Modbus TCP/IP to OPC UA Server Gateway is listed as Active / Available from OEM. This active ProSoft gateway is available for multi-protocol data integration. Apter Power can check OPC UA and controller application requirements.
ProSoft PLX32-EIP-MBTCP-UA EtherNet/IP to Modbus TCP/IP to OPC UA Server Gateway Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ProSoft PLX32-EIP-MBTCP-UA EtherNet/IP to Modbus TCP/IP to OPC UA Server Gateway Specs

General

  • Manufacturer ProSoft Technology
  • Model PLX32-EIP-MBTCP-UA
  • Condition New Original ready stock
  • Product Family PLX3x Gateways
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

PLX32-EIP-MBTCP-UA Protocols details

  • Function: EtherNet/IP Class 1 and Class 3 communications
  • Protocol: Modbus TCP/IP Client and Server roles
  • Capacity: Simultaneous access to common process data
  • Operation: Certificates, user access, and time settings require commissioning review.

PLX32-EIP-MBTCP-UA OPC details

  • Integration: Integrated OPC UA Server
  • Interface: Up to 10 simultaneous client connections
  • Configuration: Sign and encryption policy support
  • Application: Certificates, user access, and time settings require commissioning review.

PLX32-EIP-MBTCP-UA Networking details

  • Diagnostics: Two independent Ethernet ports
  • Setup: Separate controller and OPC UA subnets
  • Verification: Optional SD-card configuration backup
  • Maintenance: Certificates, user access, and time settings require commissioning review.
Description
The PLX32-EIP-MBTCP-UA provides tri-directional data exchange among EtherNet/IP, Modbus TCP/IP, and an integrated OPC UA Server.

The PLX32-EIP-MBTCP-UA uses separate Ethernet ports so industrial controller networks and the OPC UA Server can operate on different subnets while sharing process data.

The PLX32-EIP-MBTCP-UA supports simultaneous OPC UA sessions, configurable security policies, an embedded EDS Add-On Profile, and optional SD-card configuration backup.
Alternative Names
PLX32 EIP MBTCP UA PLX32EIPMBTCPUA ProSoft PLX32-EIP-MBTCP-UA PST PLX32-EIP-MBTCP-UA PLX32-EIP-MBTCP-UA OPC Gateway PLX32-EIP-MBTCP-UA Protocol Gateway PLX32-EIP-MBTCP-UA Datasheet PLX32-EIP-MBTCP-UA Manual
Technical notes
PLX32-EIP-MBTCP-UA combines EtherNet/IP, Modbus TCP/IP, and an OPC UA Server. Verify subnet design, client/server roles, OPC UA security, connection limits, and firmware.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is ProSoft PLX32-EIP-MBTCP-UA?
PLX32-EIP-MBTCP-UA is a EtherNet/IP to Modbus TCP/IP to OPC UA Server Gateway according to ProSoft's official product documentation.
Which systems are compatible with PLX32-EIP-MBTCP-UA?
PLX32-EIP-MBTCP-UA is intended for EtherNet/IP devices, Modbus TCP/IP networks, and OPC UA clients. Verify the installed controller, protocol role, firmware, and wiring before commissioning.
What is the main application of PLX32-EIP-MBTCP-UA?
PLX32-EIP-MBTCP-UA is used for making EtherNet/IP and Modbus TCP/IP process data available through an OPC UA Server as described in the official ProSoft documentation.
Which specifications should be checked before installing PLX32-EIP-MBTCP-UA?
PLX32-EIP-MBTCP-UA: verify Ethernet subnet layout, EtherNet/IP connections, Modbus roles, OPC UA sessions, security policy, power, and temperature against the official datasheet before installation.
What is the lifecycle status of PLX32-EIP-MBTCP-UA?
PLX32-EIP-MBTCP-UA is classified as Active / Available from OEM from the reviewed ProSoft product and lifecycle resources.
Does PLX32-EIP-MBTCP-UA require a replacement model?
PLX32-EIP-MBTCP-UA has no manufacturer-stated replacement requirement in the reviewed official resources. Confirm protocol and system compatibility before any substitution.
Where can I find documentation and request a quote for PLX32-EIP-MBTCP-UA?
PLX32-EIP-MBTCP-UA official datasheet is listed first in the Manuals tab; send quantity, system details, destination, and documentation needs to Apter Power for quotation.
What happens to PLX32-EIP-MBTCP-UA OPC UA connection if NTP becomes unreachable?
PLX32-EIP-MBTCP-UA may enter Not Provisioned when NTP is unreachable; reconnection resumes automatically after NTP service returns.

Product Browsing History