    Apter Power provides 6ES7153-4AA01-0XB0 quotations, product manuals and ET 200M configuration support.

6ES7153-4AA01-0XB0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6ES7153-4AA01-0XB0 is a SIMATIC ET 200M IM 153-4 PN ST interface module with two PROFINET ports and capacity for 12 modules.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7153-4AA01-0XB0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7153-4AA01-0XB0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7153-4AA01-0XB0
  • Product Family:
    Siemens ET 200M
  • Product Type:
    PROFINET Interface Module
  • Stock:
    1
  • PROFINET Ports:
    2
  • Modules per Station:
    12 maximum
  • Supply Range:
    20.4–28.8 V DC
  • Backplane Output:
    5 V DC, maximum 1.5 A
  • Process Data:
    192 bytes input and 192 bytes output
  • Media Redundancy:
    MRP supported
  • Real-Time Mode:
    IRT high performance supported
  • Unsupported Modules:
    F modules and HART modules
  • Weight:
    0.474 lbs (0.215 kg)
  • Estimated shipping dimensions:
    4×12.5×11.8cm
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals PROFINET Ports Shared Device IRT Timing Configuration Limits

Features:

  • Connects a SIMATIC ET 200M station to PROFINET IO through two integrated ports.
  • Supplies the module backplane and coordinates as many as twelve S7-300 modules.
  • Supports MRP, Shared Device and IRT high-performance communication functions.
The two Ethernet ports combine network forwarding with access to the ET 200M backplane.

Controller ownership and topology configuration determine how advanced PROFINET functions operate.

The ST order code sets compatibility limits that exclude F, HART and H-system redundant configurations.

The Siemens 6ES7153-4AA01-0XB0 PROFINET Interface Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7153-4AA01-0XB0 IM 153-4 PN ST Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Two-Port Network Path

  • Port pair: X1 P1 and X1 P2 form the integrated PROFINET switch.
  • Line routing: One port can receive the network while the other continues it to the next device.
  • Redundancy: Both interfaces participate in a configured Media Redundancy Protocol ring.
  • Port evidence: LINK and RX/TX indicators separate physical connection from frame activity.

Controller Ownership

  • Submodule split: Two IO controllers can own different modules within one ET 200M station.
  • RUN condition: Both controllers remain in RUN for their configured outputs to operate normally.
  • Program handling: OB83, OB85 and OB122 cover station changes and access events.
  • Engineering rule: Each submodule is assigned to the intended controller only once.

Isochronous Communication Setup

  • Operating mode: The interface supports IRT high-performance communication.
  • Topology requirement: Every physical port connection is entered in the project.
  • Schedule basis: The configured path lets the controller calculate deterministic transfer timing.
  • Mismatch result: Incorrect topology prevents the planned IRT relationship from being established.

Station-Scope Boundaries

  • Module count: One 6ES7153-4AA01-0XB0 manages up to twelve S7-300 modules.
  • Address area: The station supports 192 input bytes and 192 output bytes.
  • Excluded I/O: F modules and HART modules are outside the ST version's supported scope.
  • Redundant control: H-system CPU redundancy is not provided by this interface variant.
Description
At the head of a SIMATIC ET 200M station, Siemens 6ES7153-4AA01-0XB0 is the IM 153-4 PN ST interface module that connects the distributed I/O assembly to PROFINET IO. Its two Ethernet ports carry the network path while the backplane distributes communication and 5 V power to as many as twelve S7-300 modules.

The two-port switch in 6ES7153-4AA01-0XB0 supports line connections, Media Redundancy Protocol and IRT high-performance operation. IRT high performance requires the network topology to be configured, whereas MRP uses the two interfaces as part of the managed redundancy ring.

Shared Device operation lets two IO controllers divide the assigned submodules of 6ES7153-4AA01-0XB0. Both controllers must remain in RUN for their allocated outputs to operate as configured, and the controller programs must include the required organization blocks for station and access events.

A 24 V DC supply powers 6ES7153-4AA01-0XB0 and feeds its 5 V/1.5 A backplane output. This ST version does not support F modules, HART modules or H-system redundant CPUs, so those compatibility limits are checked separately from the general twelve-module station capacity.
Alternative Names
6ES71534AA010XB0 6ES7153 4AA01 0XB0 6ES7 153-4AA01-0XB0 Siemens 6ES7153-4AA01-0XB0 SIMATIC ET 200M 6ES7153-4AA01-0XB0 IM 153-4 PN ST 6ES7153-4AA01-0XB0 6ES7153-4AA01-0XB0 Interface Module 6ES7153-4AA01-OXB0
Technical notes
6ES7153-4AA01-0XB0 connects up to twelve ET 200M modules through two PROFINET ports but excludes F, HART and H-system configurations.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can the Ethernet link LEDs be active while 6ES7153-4AA01-0XB0 still has no process data?
The link LEDs on 6ES7153-4AA01-0XB0 confirm the physical port connection only; the PROFINET device name, IP assignment, station configuration and controller state must also match.
What must be configured before IRT high performance can run through 6ES7153-4AA01-0XB0?
The network topology for 6ES7153-4AA01-0XB0 must be defined in the engineering project so the IRT schedule can use the correct port-to-port path.
Why do outputs assigned through Shared Device stay inactive on 6ES7153-4AA01-0XB0?
Both IO controllers sharing 6ES7153-4AA01-0XB0 must be in RUN and each must own the correct submodules; a stopped partner can affect the configured output behavior.
Can an ET 200M station containing F modules be headed by 6ES7153-4AA01-0XB0?
No. The ST hardware identified by 6ES7153-4AA01-0XB0 does not support F modules, so that station requires a compatible interface-module variant.
How much address space should be planned for 6ES7153-4AA01-0XB0?
The 6ES7153-4AA01-0XB0 station provides up to 192 input bytes and 192 output bytes across the configured ET 200M modules.
Which engineering paths can load the hardware configuration for 6ES7153-4AA01-0XB0?
The 6ES7153-4AA01-0XB0 can be configured with the documented STEP 7 TIA Portal or STEP 7 Classic support packages, or by the corresponding GSD file.