Siemens C98043-A7010-L1 is a SIMOREG DC-MASTER field-supply power section for 15 A converters, forming the controlled bridge for a 3 A rated DC field circuit.
In Stock
Ships by Tuesday, September 29
Fast Shipping Available
Get a quick price for C98043-A7010-L1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for C98043-A7010-L1

  • Manufacturer:
    Siemens
  • Part Number:
    C98043-A7010-L1
  • Product Family:
    Siemens SIMOREG DC-MASTER
  • Product Type:
    Field Supply Power Section
  • Stock:
    1
  • Converter Armature Rating:
    15 A DC
  • Field Current Rating:
    3 A DC
  • Field Supply Terminals:
    3U1, 3W1
  • DC Field Terminals:
    3D, 3C
  • Controlled Bridge:
    V7, V8
  • R1:
    0R1
  • R2:
    0R1
  • Primary Conductor Passes:
    2
  • Gating Lead Type:
    Betatherm 145
  • Gating Lead Cross-Section:
    1 mm²
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Field Bridge 15 A Wiring Lead Identification Offset Adjustment

Features:

  • Fits the 15 A SIMOREG DC-MASTER converter class.
  • Supplies a field circuit rated at 3 A DC.
  • Uses a two-pass primary-conductor arrangement with equal R1/R2 values.
C98043-A7010-L1 is the lower-current member of the A7010 field-supply pair and is selected by the converter’s 15 A armature rating.

Its equal sensing-resistor values and doubled primary path establish the L1 current-measurement arrangement.

Field input, controlled bridge, and DC field output are separated into clearly named connection points for tracing during integration.

The Siemens C98043-A7010-L1 Field Supply Power Section may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens C98043-A7010-L1 Field Supply Power Section Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Supply, Switching, and Field Output

  • Input Pair: 3U1 and 3W1 supply the bridge.
  • Control Devices: V7 and V8 form the thyristor pair.
  • Output Pair: 3D and 3C connect to the DC field circuit.
  • Rated Field: The L1 bridge is rated at 3 A DC.

Two-Pass Measurement Path

  • Armature Class: The L1 arrangement belongs to 15 A converters.
  • Primary Path: The primary conductor is fed through twice.
  • R1: The R1 element is 0R1.
  • R2: The R2 element is also 0R1.

Gate and Cathode Marking

  • Gate Color: Gate leads are identified in yellow.
  • Cathode Color: Cathode leads are identified in red.
  • Lead Type: Betatherm 145 cable is specified for gating.
  • Lead Size: The stated cross-section is 1 mm².

Restoring Field-Current Zero

  • Trigger: Repeat the adjustment after the field board is replaced.
  • Parameter: Use P051 = 22 for the internal offset routine.
  • Purpose: The routine sets the zero point of field-current sensing.
  • Power State: Carry out physical replacement only with supplies isolated.
Description
For low-current SIMOREG DC-MASTER assemblies, Siemens C98043-A7010-L1 serves as the field-supply power section. The L1 configuration is tied to the 15 A armature-current class and supplies a field circuit rated at 3 A DC.

Siemens C98043-A7010-L1 places identical 0R1 values at R1 and R2 in the current-sensing network. In the 15 A connection layout, the primary conductor passes through twice, distinguishing the L1 current path from the single-pass 30 A arrangement.

At the bridge boundary, Siemens C98043-A7010-L1 accepts the field supply on 3U1 and 3W1 and presents the DC field connection on 3D and 3C. Thyristor positions V7 and V8 are driven through 1 mm² Betatherm 145 gate leads.

The maintenance procedure for Siemens C98043-A7010-L1 requires an isolated converter and ESD handling before board removal. After installation, P051 = 22 repeats the internal offset setting for the field-current measurement path.
Alternative Names
C98O43-A7010-L1 C98043 A7010 L1 C98043A7010L1 Siemens C98043-A7010-L1 SIMOREG C98043-A7010-L1 C98043-A7010-L1 field section A7010-L1 15A power board C98043-A70I0-L1
Technical notes
Siemens C98043-A7010-L1 uses equal 0R1 values at R1 and R2 and a two-pass primary-conductor route for the 15 A class.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which ratings identify Siemens C98043-A7010-L1 rather than the L2 board?
Siemens C98043-A7010-L1 is specified for 15 A armature current and 3 A field current, with 0R1 used for both R1 and R2.
Why is the primary conductor routed twice for C98043-A7010-L1?
The official 15 A connection layout requires the C98043-A7010-L1 primary conductor to pass through twice; keep that routing when matching the original assembly.
Which terminals define the field circuit on C98043-A7010-L1?
C98043-A7010-L1 receives the field supply at 3U1/3W1 and connects the DC field side at 3D/3C.
How are gate and cathode leads identified around Siemens C98043-A7010-L1?
Around Siemens C98043-A7010-L1, gate leads are yellow and cathode leads are red; the gate-lead specification is Betatherm 145, 1 mm².
Can C98043-A7010-L1 be substituted for a 30 A L2 section?
Do not treat C98043-A7010-L1 as the 30 A version: its documented ratings and primary-conductor routing are different from L2.
Which parameter restores the field-current offset after changing C98043-A7010-L1?
Use P051 = 22 after changing C98043-A7010-L1 to repeat the internal offset adjustment.