C98043-A7010-L2-5

/ 4.9
1001 reviews | Need a Specific Revision?
The Siemens C98043-A7010-L2-5 is the L2 field-supply power-section version used with SIMOREG DC-MASTER 30 A converters and a 5 A rated field circuit.
In Stock
Ships by Tuesday, September 29
Fast Shipping Available
Get a quick price for C98043-A7010-L2-5
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for C98043-A7010-L2-5

  • Manufacturer:
    Siemens
  • Part Number:
    C98043-A7010-L2-5
  • Product Family:
    Siemens SIMOREG DC-MASTER
  • Product Type:
    Field Supply Power Section
  • Stock:
    1
  • Base Functional Variant:
    C98043-A7010-L2
  • Converter Armature Rating:
    30 A DC
  • Field Current Rating:
    5 A DC
  • Field Supply Input:
    3U1, 3W1
  • Field Circuit Output:
    3D, 3C
  • Field Bridge Devices:
    V7, V8
  • R1:
    0R1
  • R2:
    0R05
  • Primary Conductor Passes:
    1
  • Gate Lead Specification:
    Betatherm 145, 1 mm²
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Power Flow Connector Map Gate Wiring Service Setup

Features:

  • Carries the complete L2-5 field-section identity.
  • Uses the 30 A armature and 5 A field-current configuration.
  • Routes field power through V7/V8 between 3U1/3W1 and 3D/3C.
C98043-A7010-L2-5 combines the L2 electrical arrangement with the visible -5 version suffix, allowing the delivered board label to be matched without dropping characters.

Its controlled bridge and sensing resistors form one continuous field-current path, separate from the armature switching network.

The module participates in both the standard block diagram and the detailed 15–30 A converter connection layouts used by the platform.

The Siemens C98043-A7010-L2-5 Field Supply Power Section may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens C98043-A7010-L2-5 Field Supply Power Section Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Controlled Field-Path Sequence

  • Entry: The field supply arrives at 3U1 and 3W1.
  • Control Stage: V7 and V8 regulate the bridge path.
  • Exit: 3D and 3C carry the DC field connection.
  • Rating: The L2 path is rated for 5 A DC field current.

Connector and Terminal Reference

  • XF1: XF1 marks one connector boundary of the bridge assembly.
  • XF2: XF2 provides the companion field-bridge connection group.
  • Terminal Pair: 3U1/3W1 remain distinct from 3D/3C.
  • Converter Class: The mapped arrangement belongs to 30 A units.

Gate Leads and Measurement Network

  • Lead Material: Gate leads use Betatherm 145 cable.
  • Cross-Section: Each specified gate lead is 1 mm².
  • Device Labels: Gate and cathode points are identified around V7 and V8.
  • Sensing Values: The L2 bridge uses 0R1 at R1 and 0R05 at R2.

Isolation and Zero-Point Recovery

  • Safe State: All inputs, outputs, and electronics supplies must be isolated.
  • Static Control: Discharge static electricity before contact with the PCB.
  • Zero Point: P051 = 22 recalibrates the field-current sensing offset.
  • Reference Match: Keep the complete C98043-A7010-L2-5 identifier when checking the supplied board.
Description
The full Siemens C98043-A7010-L2-5 designation identifies the -5 hardware marking of the L2 field-supply power section in a SIMOREG DC-MASTER converter. Siemens C98043-A7010-L2-5 belongs to the 30 A armature-current class and provides the controlled path for a 5 A DC field circuit.

For board matching, Siemens C98043-A7010-L2-5 retains the XF1 and XF2 connector groups around the V7/V8 bridge. The incoming field supply is separated at 3U1 and 3W1 from the 3D and 3C DC-field output, allowing each boundary of the bridge to be traced without treating the assembly as part of the armature circuit.

The sensing arrangement on Siemens C98043-A7010-L2-5 combines 0R1 at R1 with 0R05 at R2 and a single pass of the primary conductor. That combination defines the L2 measurement path used for the 30 A converter class, while the Betatherm 145 gate conductors use a 1 mm² cross-section.

Before Siemens C98043-A7010-L2-5 is inserted or removed, all connected supplies are isolated and electrostatic discharge precautions are applied. After replacement, P051 = 22 repeats the internal zero-point adjustment for the field-current sensing circuit.
Alternative Names
C98O43-A7010-L2-5 C98043 A7010 L2 5 C98043A7010L25 Siemens C98043-A7010-L2-5 SIMOREG C98043-A7010-L2-5 C98043-A7010-L2-5 field board A7010-L2-5 power section C98043-A70I0-L2-5
Technical notes
C98043-A7010-L2-5 retains the L2 30 A/5 A field-supply configuration; the complete -5 suffix identifies the supplied hardware version.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which marking must remain visible when C98043-A7010-L2-5 is matched to an installed board?
Retain the complete C98043-A7010-L2-5 marking, including the -5 ending, when comparing the replacement with the installed hardware.
What connector groups should be checked before moving field wiring to C98043-A7010-L2-5?
Check XF1 and XF2 on C98043-A7010-L2-5, then confirm that 3U1/3W1 remain the incoming pair and 3D/3C remain the DC-field pair.
How does the C98043-A7010-L2-5 sensing path represent the 30 A converter class?
C98043-A7010-L2-5 uses one primary-conductor pass with 0R1 at R1 and 0R05 at R2 for the L2 current-measurement arrangement.
What gate-lead construction is specified around V7 and V8 on C98043-A7010-L2-5?
The V7/V8 gate connections on C98043-A7010-L2-5 use Betatherm 145 conductors with a 1 mm² cross-section.
Which terminals must remain separated when reconnecting C98043-A7010-L2-5?
Keep the 3U1/3W1 field-supply inputs distinct from the 3D/3C DC-field outputs on C98043-A7010-L2-5.
Why is P051 = 22 run after installing C98043-A7010-L2-5?
P051 = 22 repeats the internal zero-point adjustment for the field-current sensing path after C98043-A7010-L2-5 is installed.