IC697MDL750
General Electric IC697MDL750
IC697MDL750
IC697MDL750
General Electric IC697MDL750
IC697MDL750
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>

IC697MDL750

/ 4.9
1001 reviews | Need a Specific Revision?
GE IC697MDL750 supplies thirty-two 24/48 VDC output points in four isolated banks for dense positive-logic load control within a Series 90-70 system.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for IC697MDL750
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC697MDL750

  • Manufacturer:
    General Electric
  • Part Number:
    IC697MDL750
  • Product Family:
    GE 90-70 Series PLC
  • Product Type:
    24/48 VDC 0.5 A 32-Point Output Module
  • Stock:
    1
  • Output Count:
    32
  • Group Arrangement:
    Four isolated groups of eight
  • Rated Voltage:
    24 or 48 VDC
  • Operating Range:
    20–60 VDC
  • Point Current:
    0.5 A maximum
  • Group Current:
    2 A maximum for Version E and earlier
  • Internal Fuses:
    None
  • Suggested External Fuse:
    0.75 A, 250 V fast acting per point
  • Inrush:
    10 A maximum for 20 ms
  • Voltage Drop:
    1 V maximum
  • On/Off Response:
    1 ms maximum
  • Leakage:
    1 mA maximum
  • Backplane Demand:
    0.25 A at 5 VDC
  • Isolation:
    1500 V to backplane; 500 V between groups
  • Dimensions:
    4 × 22 × 29 cm
  • Weight:
    0.58 kg
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Revision Impact Circuit Protection Service Application
  • Thirty-two positive-logic DC output points
  • Four isolated eight-channel field-power groups
  • Revision-dependent current and mechanical-keying behavior

IC697MDL750 is a Series 90-70 output module that provides thirty-two positive-logic channels for switching compatible 24 VDC and 48 VDC field loads.

The outputs are divided into four electrically isolated banks of eight points with separate field-power connections. Each channel supports moderate steady-state current and documented short-duration inrush for suitable solenoids, contactors, indicators, and similar DC devices.

The module has no internal output fuses, making correctly selected external protection essential. Before replacement, verify the complete hardware suffix because Version E and earlier differ from Version F and later in documented group-current and mechanical-keying behavior.

Availability, condition, price, and shipping time for IC697MDL750 are confirmed during quotation.

General Electric IC697MDL750 24/48 VDC 0.5 A 32-Point Output Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Identify whether hardware is Version E or earlier
  • Apply the documented two-ampere group limit where required
  • Check whether the installed slot uses mechanical keying
  • Provide point protection where the design requires it
  • Use the specified fast-acting fuse characteristic
  • Investigate any operated external fuse before reset
  • Verify every group feed and common
  • Measure voltage at representative loads
  • Prove the configured fault response
  • High-density 24/48 VDC load switching
  • Positive-logic solenoid and indicator control
  • Revision-controlled IC697MDL750 replacement
Description
IC697MDL750 provides four eight-point output banks operating from 20 to 60 VDC. Each point is rated for 0.5 A and can handle a documented 10 A, 20 ms surge.

The module contains no output fuses. If circuit protection is required, each point should receive the specified external fast-acting fuse or protection selected by the panel design.

Hardware version changes are operationally important: Version E and earlier retain a 2 A group limit and mechanical keying, while Version F and later remove that stated group limit and do not use the same keying arrangement.
Revisions

Revision Part #

Also known as

IC697MDL750A
IC697MDL750-A, Series A, Rev A
IC697MDL750B
IC697MDL750-B, Series B, Rev B
IC697MDL750C
IC697MDL750-C, Series C, Rev C
IC697MDL750D
IC697MDL750-D, Series D, Rev D
IC697MDL750E
IC697MDL750-E, Series E, Rev E
IC697MDL750F
IC697MDL750-F, Series F, Rev F
Alternative Names
IC697MDL750 32-Point DC Output Series 90-70 IC697MDL750 IC 697 MDL 750 GE Fanuc IC697MDL750 GE IC697MDL750
Technical notes
IC697MDL750 has no internal output fusing; preserve external protection, group feeds, fault-mode programming, and the revision-dependent current and mechanical-keying differences between pre-F and later hardware.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Does GE IC697MDL750 contain output fuses?
No. The module has no internal output fuses; provide the documented external protection where the machine design requires point-level fault isolation.
Why is the GE IC697MDL750 hardware suffix important?
Version E and earlier have a documented 2 A group limit and mechanical keying, while Version F and later are described differently. Preserve the installed revision requirement.
Can GE IC697MDL750 drive an incandescent or high-inrush load?
Only after checking steady current, the 10 A for 20 ms surge limit, repetition rate, wiring protection and the power supply's ability to support the transient.
How should GE IC697MDL750 field power be distributed?
Feed each isolated eight-point bank through its assigned common and protection. Do not assume the four group power terminals are internally linked.
What happens to GE IC697MDL750 outputs on a controller fault?
The configured fault mode can hold the existing state or turn outputs off. Confirm that selection against the process safe state before commissioning.
Why can a GE IC697MDL750 LED be on while the device remains off?
The LED reports the logic-side command, not load current. Check group power, common polarity, external fuse, conductor continuity and the connected device.
What should be recorded before replacing GE IC697MDL750?
Capture the complete suffix, slot, output references, group feeds, external fuses, fault-mode setting and load inrush so the replacement preserves both wiring and behavior.