Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides PLX31-EIP-MBTCP quotations, official documents, sourcing, and protocol-mapping guidance.

PLX31-EIP-MBTCP

/ 4.9
1001 reviews | Need a Specific Revision?
ProSoft PLX31-EIP-MBTCP is an EtherNet/IP to Modbus TCP/IP gateway for bidirectional industrial data exchange.
In Stock
Ships by Sunday, October 18
Fast Shipping Available
Get a quick price for PLX31-EIP-MBTCP
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PLX31-EIP-MBTCP

  • Manufacturer:
    ProSoft
  • Part Number:
    PLX31-EIP-MBTCP
  • Product Family:
    ProSoft
  • Product Type:
    EtherNet/IP-to-Modbus TCP/IP Communication Gateway
  • Stock:
    1
  • Number of Class 3 Server Connections:
    5
  • Supported PLC Types:
    PLC2, PLC5, SLC, CLX, CMPLX, MICROLX
  • Supported Message Types:
    PCCC and CIP
  • Class 3 Client Connections:
    Connected: 2; Unconnected: 1
  • Number of Class 1 I/O Connections:
    2
  • I/O connection sizes:
    248/248
  • Max RPI time:
    5 ms per connection
  • CIP Services Supported:
    0x4C - CIP Data Table Read; 0x4D - CIP Data Table Write; CIP Generic
  • Supported Clients:
    10
  • Command List:
    Up to 160 fully configurable Client commands
  • Status Data:
    Error codes reported individually for each command
  • Command List Polling:
    Each command can be individually enabled or disabled; write-only-on-data-change is available
  • Power Supply:
    24 VDC nominal 10 to 36 VDC allowed Positive, Negative, GND Terminals
  • Current Load:
    24 VDC nominal @ 300 mA; 10 to 36 VDC @ 610 mA maximum
  • Operating Temperature:
    -25°C to 70°C (-13°F to 158°F)
  • Storage Temperature:
    -40°C to 80°C (-40°F to 176°F)
  • Vibration:
    IEC 60068-2-6; 5G @ 10 to 150 Hz
  • Relative Humidity:
    5% to 95% RH with no condensation
  • Shipped With Each Unit:
    2.5 mm screwdriver; J180 Power Connector
  • Weight:
    0.5 kg
  • Estimated shipping dimensions:
    5.38 x 1.99 x 4.38 in / 13.67 x 5.05 x 11.13 cm
  • Tariff Code:
    8517.62
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications EtherNet/IP Modbus TCP Configuration

Features:

  • Bidirectional EtherNet/IP and Modbus TCP/IP data exchange
  • Multiple Modbus TCP/IP client and server connections
  • Embedded EDS Add-On Profile and optional SD-card backup
ProSoft PLX31-EIP-MBTCP bridges EtherNet/IP controllers and Modbus TCP/IP equipment through one independently configured industrial Ethernet gateway.

EtherNet/IP Class 1 I/O and Class 3 messaging can be mapped to Modbus TCP/IP client or server transactions. This lets a controller exchange selected data with Modbus devices without custom protocol programming.

Review connection counts, command timing, register addressing, data types, IP subnets, and controller assembly mapping before deployment. Network segmentation and message update rates should follow the official configuration guide.
The ProSoft PLX31-EIP-MBTCP EtherNet/IP-to-Modbus TCP/IP Communication Gateway is listed as Active / Available from OEM. This ProSoft gateway remains available for EtherNet/IP and Modbus TCP/IP applications. Apter Power offers quotation and network-mapping support.
ProSoft PLX31-EIP-MBTCP EtherNet/IP-to-Modbus TCP/IP Communication Gateway Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ProSoft PLX31-EIP-MBTCP EtherNet/IP to Modbus TCP/IP Communication Gateway Specs

General

  • Manufacturer ProSoft Technology
  • Model PLX31-EIP-MBTCP
  • Condition New Original ready stock
  • Product Family PLX3x Gateways
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

PLX31-EIP-MBTCP EtherNet/IP details

  • Function: Class 1 I/O connections
  • Protocol: Class 3 connected and unconnected messaging
  • Capacity: Embedded EDS Add-On Profile
  • Operation: Data mapping links controller assemblies with Modbus registers.

PLX31-EIP-MBTCP Modbus details

  • Integration: Multiple Client and Server connections
  • Interface: Configurable command list
  • Configuration: Individual command status reporting
  • Application: Data mapping links controller assemblies with Modbus registers.

PLX31-EIP-MBTCP Configuration details

  • Diagnostics: ProSoft Configuration Builder support
  • Setup: Optional SD-card configuration backup
  • Verification: ProSoft Discovery Service for initial addressing
  • Maintenance: Data mapping links controller assemblies with Modbus registers.
Description
The PLX31-EIP-MBTCP transfers data bidirectionally between EtherNet/IP controllers or devices and Modbus TCP/IP controllers or devices.

The PLX31-EIP-MBTCP supports multiple Modbus TCP/IP client and server connections together with EtherNet/IP Class 1 and Class 3 communications.

The PLX31-EIP-MBTCP includes data prioritization, an embedded EDS Add-On Profile, an optional SD-card configuration backup, and ProSoft configuration tools.
Alternative Names
PLX31 EIP MBTCP PLX31EIPMBTCP ProSoft PLX31-EIP-MBTCP PST PLX31-EIP-MBTCP PLX31-EIP-MBTCP Protocol Gateway PLX31-EIP-MBTCP Modbus Gateway PLX31-EIP-MBTCP Datasheet PLX31-EIP-MBTCP Manual
Technical notes
PLX31-EIP-MBTCP is an EtherNet/IP to Modbus TCP/IP gateway with simultaneous protocol communications. Verify client/server roles, command mapping, connection limits, power, and subnet design.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is ProSoft PLX31-EIP-MBTCP?
PLX31-EIP-MBTCP is a EtherNet/IP to Modbus TCP/IP Communication Gateway according to ProSoft's official product documentation.
Which systems are compatible with PLX31-EIP-MBTCP?
PLX31-EIP-MBTCP is intended for EtherNet/IP controllers or devices and Modbus TCP/IP client or server networks. Verify the installed controller, protocol role, firmware, and wiring before commissioning.
What is the main application of PLX31-EIP-MBTCP?
PLX31-EIP-MBTCP is used for bidirectional data exchange between EtherNet/IP and Modbus TCP/IP systems as described in the official ProSoft documentation.
Which specifications should be checked before installing PLX31-EIP-MBTCP?
PLX31-EIP-MBTCP: verify EtherNet/IP connection type, Modbus client/server roles, command capacity, power, Ethernet settings, and temperature against the official datasheet before installation.
What is the lifecycle status of PLX31-EIP-MBTCP?
PLX31-EIP-MBTCP is classified as Active / Available from OEM from the reviewed ProSoft product and lifecycle resources.
Does PLX31-EIP-MBTCP require a replacement model?
PLX31-EIP-MBTCP has no manufacturer-stated replacement requirement in the reviewed official resources. Confirm protocol and system compatibility before any substitution.
Where can I find documentation and request a quote for PLX31-EIP-MBTCP?
PLX31-EIP-MBTCP official datasheet is listed first in the Manuals tab; send quantity, system details, destination, and documentation needs to Apter Power for quotation.

Product Browsing History