Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides quotation, official documentation, configuration review, and PROFIBUS application support for ILX56-PBM.

ILX56-PBM

/ 4.9
1001 reviews | Need a Specific Revision?
ProSoft ILX56-PBM is a PROFIBUS DPV1 Master/Multi-Slave module for Rockwell Automation ControlLogix systems.
In Stock
Ships by Saturday, October 17
Fast Shipping Available
Get a quick price for ILX56-PBM
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ILX56-PBM

  • Manufacturer:
    ProSoft
  • Part Number:
    ILX56-PBM
  • Product Family:
    ProSoft
  • Product Type:
    PROFIBUS DPV1 Master/Multi-Slave Module
  • Stock:
    1
  • Slaves (PROFIBUS DP Master):
    Maximum 125
  • Master Input/Output:
    Maximum 244 Bytes per Slave
  • Master Input Data:
    Maximum 5000 Bytes
  • Master Acyclic Data:
    DPV1
  • Master Status data:
    88 Bytes
  • Master Output data:
    Maximum 5000 Bytes
  • Master DPV1 Services:
    Class 1 Read/Write Class 1 Alarm Class 2 Initiate/Read/Write/Abort
  • Master Services:
    Global-Control, Slave-Diagnostic, Set-Parameter
  • Master Sync, Freeze Command:
    Supported
  • Master Baud rate:
    9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud
  • Slaves (PROFIBUS DP Slave):
    Emulate up to 10 slaves
  • Input/Output:
    Maximum 244 Bytes per Slave
  • Input Data:
    Maximum 2440 Bytes
  • Acyclic Data:
    DPV1
  • Status data:
    88 Bytes
  • Output data:
    Maximum 2440 Bytes
  • DPV1 Services:
    Class 1 Read/Write, Class 1 Alarm
  • Services:
    Global-Control, Slave-Diagnostic, Set-Parameter
  • Sync, Freeze Command:
    Supported
  • Baud rate:
    9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud. Auto-detection mode is supported
  • Weight:
    0.9 kg
  • Estimated shipping dimensions:
    Standard 1756 Single-slot module
  • Tariff Code:
    8471.50.00
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Protocol Integration Diagnostics

Features:

  • PROFIBUS DPV1 Master or multi-slave operation
  • Up to 5000 bytes of cyclic input and output data in Master mode
  • Studio 5000 integration with PROFIBUS diagnostics
Designed for the ControlLogix platform, the ProSoft ILX56-PBM places PROFIBUS DPV1 master or multi-slave communication directly in the local chassis and exchanges up to 5000 bytes of cyclic I/O data.

The module supports PROFIBUS DPV0 cyclic services and DPV1 acyclic messaging. In multi-slave operation, as many as ten virtual slave nodes can be configured for communication with a PROFIBUS master.

Before commissioning, confirm chassis slot allocation, PROFIBUS cabling and termination, node addresses, GSD files, and controller tag mapping. The Add-On Profile and onboard diagnostics support configuration and troubleshooting.
The ProSoft ILX56-PBM PROFIBUS DPV1 Master/Multi-Slave Module is listed as Active / Available from OEM. This active ProSoft module is available for ControlLogix PROFIBUS projects. Apter Power can review chassis fit and provide official documentation.
ProSoft ILX56-PBM PROFIBUS DPV1 Master/Multi-Slave Module Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ProSoft ILX56-PBM PROFIBUS DPV1 Master/Multi-Slave Module Specs

General

  • Manufacturer ProSoft Technology
  • Model ILX56-PBM
  • Condition New Original ready stock
  • Product Family ILX56 ControlLogix In-Chassis Modules
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

ILX56-PBM Protocol details

  • Function: PROFIBUS DPV0 and DPV1 support
  • Protocol: Master or multi-slave operation
  • Capacity: Baud rates from 9.6 kBaud to 12 MBaud
  • Operation: Embedded diagnostics include PROFIBUS packet-capture support.

ILX56-PBM Integration details

  • Integration: ControlLogix in-chassis installation
  • Interface: Studio 5000 project integration
  • Configuration: Optional SD-card configuration backup
  • Application: Embedded diagnostics include PROFIBUS packet-capture support.

ILX56-PBM Diagnostics details

  • Diagnostics: PROFIBUS network scan support
  • Setup: Packet-capture and device diagnostics
  • Verification: Controller-tag status and control data
  • Maintenance: Embedded diagnostics include PROFIBUS packet-capture support.
Description
The ILX56-PBM allows Rockwell Automation ControlLogix processors to exchange cyclic and acyclic data with PROFIBUS DPV0 and DPV1 devices.

The ILX56-PBM can operate as a PROFIBUS DP Master or emulate multiple PROFIBUS DP slave nodes, with integration through Studio 5000 tools and module diagnostics.

The ILX56-PBM supports network commissioning features including PROFIBUS scanning, configuration backup with an optional SD card, and protocol-specific diagnostic functions.
Alternative Names
ILX56 PBM ILX56PBM ProSoft ILX56-PBM PST ILX56-PBM ILX56-PBM PROFIBUS Module ILX56-PBM ControlLogix Module ILX56-PBM Datasheet ILX56-PBM Manual
Technical notes
ILX56-PBM is a ControlLogix in-chassis PROFIBUS DPV1 Master/Multi-Slave module. Verify controller revision, PROFIBUS role, data size, and baud rate before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is ProSoft ILX56-PBM?
ILX56-PBM is a PROFIBUS DPV1 Master/Multi-Slave module according to ProSoft's official product documentation.
Which systems are compatible with ILX56-PBM?
ILX56-PBM is intended for ControlLogix processors and PROFIBUS DPV0 or DPV1 networks. Verify the installed controller, protocol role, firmware, and wiring before commissioning.
What is the main application of ILX56-PBM?
ILX56-PBM is used for linking ControlLogix controllers with PROFIBUS field devices as described in the official ProSoft documentation.
Which specifications should be checked before installing ILX56-PBM?
ILX56-PBM: verify ControlLogix compatibility, PROFIBUS role, cyclic data size, baud rate, and network configuration against the official datasheet before installation.
What is the lifecycle status of ILX56-PBM?
ILX56-PBM is classified as Active / Available from OEM from the reviewed ProSoft product and lifecycle resources.
Does ILX56-PBM require a replacement model?
ILX56-PBM has no manufacturer-stated replacement requirement in the reviewed official resources. Confirm protocol and system compatibility before any substitution.
Where can I find documentation and request a quote for ILX56-PBM?
ILX56-PBM official datasheet is listed first in the Manuals tab; send quantity, system details, destination, and documentation needs to Apter Power for quotation.