Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides quotations, documentation, sourcing support and system-integration guidance for PLX31-MBTCP-SIE.

PLX31-MBTCP-SIE

/ 4.9
1001 reviews | Need a Specific Revision?
The ProSoft PLX31-MBTCP-SIE provides bi-directional data exchange between Modbus TCP/IP controllers and Siemens Industrial Ethernet PACs.
In Stock
Ships by Sunday, October 18
Fast Shipping Available
Get a quick price for PLX31-MBTCP-SIE
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PLX31-MBTCP-SIE

  • Manufacturer:
    ProSoft
  • Part Number:
    PLX31-MBTCP-SIE
  • Product Family:
    ProSoft
  • Product Type:
    Modbus TCP/IP to Siemens Industrial Ethernet Gateway
  • Stock:
    1
  • Supported S7 Controllers:
    S7-200, S7-300, S7-400, S7-1200, and S7-1500
  • S7 Data Areas:
    DB, Inputs, Outputs, Flags, Counters, and Timers
  • Siemens Clients:
    20
  • Modbus TCP Clients:
    10
  • Modbus TCP Servers:
    5 MBAP; 5 Encapsulated
  • Client Commands:
    Up to 160
  • Ethernet:
    10/100 Mbit RJ45
  • Power Supply:
    24 VDC nominal; 10 to 36 VDC allowed
  • Operating Temperature:
    -25 to 70 °C
  • Relative Humidity:
    5% to 95%, non-condensing
  • Estimated shipping dimensions:
    13.67 x 5.05 x 11.13 cm (H x W x D)
  • Tariff Code:
    8517623990
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Protocols Compatibility Installation

Features:

  • Supports Siemens S7-200 through S7-1500 controllers
  • Modbus TCP/IP client and server operation
  • Optional SD-card configuration backup
The PLX31-MBTCP-SIE translates data between Modbus TCP/IP applications and Siemens Industrial Ethernet controllers without placing a communication module in the PLC chassis.

Siemens S7-200, S7-300, S7-400, S7-1200, and S7-1500 data areas can be addressed through the configured exchange. Data blocks, inputs, outputs, flags, counters, and timers are handled according to the selected controller connection.

Project preparation should begin with the Siemens CPU family and required data areas, followed by the Modbus register map and command schedule. Configuration discovery and optional SD-card storage simplify commissioning and later recovery.
For the ProSoft PLX31-MBTCP-SIE Modbus TCP/IP to Siemens Industrial Ethernet Gateway, Apter Power offers documentation, quotation, and controller-matching assistance.
ProSoft PLX31-MBTCP-SIE Modbus TCP/IP to Siemens Industrial Ethernet Gateway Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ProSoft PLX31-MBTCP-SIE Modbus TCP/IP to Siemens Industrial Ethernet Gateway Specs

General

  • Manufacturer ProSoft Technology
  • Model PLX31-MBTCP-SIE
  • Condition New Original ready stock
  • Product Family PLX3x Gateways
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Protocol exchange functions

  • Modbus roles: Modbus TCP/IP client and server
  • Siemens protocol: Siemens Industrial Ethernet read and write
  • Data direction: Up to 20 Siemens client connections
  • Command capacity: The Modbus TCP/IP driver supports up to 160 configurable client commands

Supported Siemens controller resources

  • Controller families: Siemens S7-200
  • Data blocks: Siemens S7-300 and S7-400
  • Process data: Siemens S7-1200 and S7-1500
  • Legacy resources: Flags, counters, and timers are available as supported Siemens data areas

Network and startup checks

  • Ethernet addressing: 10/100 Mbit Ethernet
  • Controller selection: DIN-rail enclosure
  • Register mapping: Optional SD-card configuration storage
  • Configuration backup: An optional SD card can store configuration files for recovery
Description
The PLX31-MBTCP-SIE is a communication gateway for high-speed, bi-directional data transfer between Modbus TCP/IP controllers and Siemens Industrial Ethernet systems.

The PLX31-MBTCP-SIE supports Siemens S7-200, S7-300, S7-400, S7-1200, and S7-1500 controllers. Supported Siemens data areas include data blocks, inputs, outputs, flags, counters, and timers.

On the Modbus side, the PLX31-MBTCP-SIE supports client and server operation with up to 160 configurable client commands. It also provides configuration discovery, data prioritization, and optional SD-card configuration storage.

Before commissioning the PLX31-MBTCP-SIE, verify the Siemens controller interface, Modbus register map, command list, network addressing, power supply, and environmental limits against the official datasheet.
Alternative Names
PLX31 MBTCP SIE PLX31MBTCPSIE ProSoft PLX31-MBTCP-SIE PST PLX31-MBTCP-SIE PLX31-MBTCP-SIE Siemens Ethernet Gateway PLX31-MBTCP-SIE protocol conversion between Modbus TCP/IP networks and Siemens Industrial Ethernet controllers PLX31-MBTCP-SIE Datasheet PLX31-MBTCP-SIE Manual
Technical notes
PLX31-MBTCP-SIE is a Modbus TCP/IP to Siemens Industrial Ethernet Gateway in the ProSoft PLX3x Gateways family. Verify protocol, interface, power, and environmental requirements against the official model documentation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is ProSoft PLX31-MBTCP-SIE?
PLX31-MBTCP-SIE is a Modbus TCP/IP to Siemens Industrial Ethernet Gateway for protocol conversion between Modbus TCP/IP networks and Siemens Industrial Ethernet controllers, according to the official ProSoft product data.
Which systems are compatible with PLX31-MBTCP-SIE?
PLX31-MBTCP-SIE is intended for Siemens S7-200, S7-300, S7-400, S7-1200, or S7-1500 controllers and Modbus TCP/IP client or server devices. Verify the exact installed hardware and protocol before use.
What is the main application of PLX31-MBTCP-SIE?
PLX31-MBTCP-SIE is designed for protocol conversion between Modbus TCP/IP networks and Siemens Industrial Ethernet controllers. Use only the roles and interfaces stated in the official datasheet.
Which specifications should be checked before installing PLX31-MBTCP-SIE?
PLX31-MBTCP-SIE: verify controller type, Siemens data areas, Modbus register mapping, command capacity, Ethernet addressing, and 24 VDC power.
What is the lifecycle status of PLX31-MBTCP-SIE?
PLX31-MBTCP-SIE is classified as Active / Available from OEM based on the reviewed ProSoft product and lifecycle information.
Does PLX31-MBTCP-SIE require a replacement model?
No replacement requirement for PLX31-MBTCP-SIE is stated in the reviewed official information; verify protocol, revision, and wiring before any substitution.
Where is the official documentation for PLX31-MBTCP-SIE?
The official model-related ProSoft datasheet for PLX31-MBTCP-SIE is the first item in the Manuals tab.
What information is needed to request a quote for PLX31-MBTCP-SIE?
PLX31-MBTCP-SIE enquiries should include quantity, installed system, protocol, hardware or firmware revision, delivery destination, and required documentation.

Product Browsing History